{"title":"Defrost Controls","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"icm302-heat-pump-defrost-timer-html","title":"ICM302 Heat Pump Defrost Timer","description":"\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eICM 302 Defrost Timer With High Power SPST Fan Relay Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eInput \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eVoltage: 18 to 30 VAC\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eOutput \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eType: Relay\u003cbr\u003eForm: SPST, N.O.\u003cbr\u003eRating: 1 amp @ 30VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eTime Delays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eAnti-Short Cycle Delay: 5 minutes\u003cbr\u003eDefrost Time: Fixed 10 minutes \u003cspan style=\"text-decoration: underline;\"\u003e+\u003c\/span\u003e 5%\u003cbr\u003eInterval Time Between Defrosts: Pin-selectable 30\/60\/90 minutes\u003cbr\u003ePower on Reset Time: 500ms\u003cbr\u003e Test Time: Short across test terminals reduces test time 256x\u003c\/span\u003e\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471681167434,"sku":"ICM31","price":74.24,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380754__27841.1484841586.1280.1280.jpg?v=1720527974"},{"product_id":"icm320-solid-state-defrost-control-circuit-board-html","title":"ICM320 Solid State Defrost Control Circuit Board","description":"\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eICM320 Solid State Defrost Control Circuit Board\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eInputVoltage: 18 to 30 Vac\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eOutput\u003cbr\u003eO, W2Type: Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eForm: DPST, N.O.\u003cbr\u003eRating: 2 amps @ 24 VAC DF1, DF2\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eType: Relay\u003cbr\u003eForm: SPST, N.O.\u003cbr\u003eRating: 10 amps @ 240 VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eTime Delays\u003cbr\u003eDefrost Time: Fixed 10 minutes \u003cspan style=\"text-decoration: underline;\"\u003e+\u003c\/span\u003e 5%\u003cbr\u003eInterval Time Between Defrosts: Pin-selectable 30\/50\/90 minutes\u003cbr\u003eTest Time: Short across test terminals reduces test time 256x\u003cbr\u003ePower on Reset Time: 500ms\u003c\/span\u003e\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471681560650,"sku":"ICM311","price":79.96,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380757__24514.1487179548.1280.1280.jpg?v=1720527970"},{"product_id":"icm318-heat-pump-defrost-control-timer-html","title":"ICM318 Heat Pump Defrost Control Timer","description":"\u003cp\u003eICM318 Heat Pump Defrost Control Timer\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eUltra low cost \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eDirect replacement for GOODMAN: B1226008, ICM: W1001-4, ICMW1001-4, TRANE: CNT02901 \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eTime and temperature control \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eOutdoor fan and reversing valve relay integrated into design \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eHigh installed base \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-size: medium;\"\u003eInput\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eVoltage: 18 to 30 Vac\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-size: medium;\"\u003eOutput\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eO, X2\u003cbr\u003eType: Relay\u003cbr\u003eForm: DPST, N.O.\u003cbr\u003eRating: 1 amp @ 30 VAC\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eDF1, DF2\u003cbr\u003eType: Relay\u003cbr\u003eForm: SPST, N.O.\u003cbr\u003eRating: 1\/2 HP @ 240 VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eTime Delays\u003cbr\u003eDefrost Time: Fixed 10 minutes \u003cspan style=\"text-decoration: underline;\"\u003e+\u003c\/span\u003e 5%\u003cbr\u003eInterval Time Between Defrosts: Pin-selectable 30\/60\/90 minutes\u003cbr\u003eTest Time: Short across test terminals reduces test time 256x\u003cbr\u003ePower on Reset Time: 500ms\u003c\/span\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471681822794,"sku":"ICM312","price":60.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/3169__80047.1484844169.1280.1280.jpg?v=1720527972"},{"product_id":"icm319-defrost-control-circuit-board-nordyne-624519a-html","title":"ICM319 Defrost Control Circuit Board Nordyne 624519A","description":"\u003cp\u003eDefrost Control - replacement for Nordyne 624519A controls\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReplacement for Nordyne 624519A \u003c\/li\u003e\n\u003cli\u003eLow cost, time and temperature defrost \u003c\/li\u003e\n\u003cli\u003eTime and temperature terminate \u003c\/li\u003e\n\u003cli\u003eTest pins reduce test time by 256X \u003c\/li\u003e\n\u003cli\u003eHOLD input tracks compressor run times \u003c\/li\u003e\n\u003cli\u003eRecycle function melts frost on coil \u003c\/li\u003e\n\u003cli\u003eIntegral short cycle protection \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003cbr\u003eCan Be Used To Replace: \u003cbr\u003eICM: DFORB24A2I300 \u003cbr\u003eNordyne: 624519A\u003cbr\u003e\u003cbr\u003eSpecifications: \u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 18-30 VAC \u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz \u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Relay Output: 1\/2 HP fan @ 240 VAC \u003c\/li\u003e\n\u003cli\u003eStrip Heat, Reversing Valve Outputs: 24 Vac, 1 amp \u003c\/li\u003e\n\u003cli\u003eAnti-Short Cycle Time: 5 minutes \u003c\/li\u003e\n\u003cli\u003eDefrost Time: Fixed 10 minutes \u003c\/li\u003e\n\u003cli\u003eInterval Time Between Defrosts: Pin-selectable 30\/60\/90 min \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471681953866,"sku":"ICM319","price":35.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/13983160__24482.1522183029.1280.1280.jpg?v=1720527974"},{"product_id":"icm300-heat-pump-defrost-timer-html","title":"ICM300 Heat Pump Defrost Timer","description":"\u003cp\u003eICM300 Heat Pump Defrost Timer\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e Ultra low cost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003ePin-for-pin compatible with OEM type 621 controls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eSimple time and temperature control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eMust have external relays for fan, reversing valve and auxiliary heat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eHigh installed base \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eInput \u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eVoltage: 18 to 30 VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eFrequency: 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eOutput \u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eType: Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eForm: SPST, N.O.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eRating: 1 amp\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eÃ‚Â \u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eTime Delays\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eDefrost Time: Fixed 10 minutes + 5%\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eInterval Time between defrosts: Pin-selectable 30\/60\/90 min\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003ePower on Reset Time: 500ms\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eTest Time: Short across test terminals reduces test time 256x\u003c\/span\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471682314314,"sku":"ICM32","price":29.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380752__22541.1484844170.1280.1280.jpg?v=1720527975"},{"product_id":"icm-icm321-solid-state-defrost-control-icm-321c-html","title":"ICM ICM321 Solid State Defrost Control ICM 321C","description":"\u003cp\u003eICM321 Solid State Defrost Control\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003cbr\u003e Voltage: 18 to 30 Vac\u003cbr\u003e Frequency: 50\/60 Hz\u003cbr\u003e Power Consumption: 1 watt max.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003cbr\u003e O, W2\u003cbr\u003e Type: Relay\u003cbr\u003e Form: DPST, N.O.\u003cbr\u003e Rating: 1 amp @ 30 VAC resistive\u003cbr\u003e T1, T2\u003c\/p\u003e\u003cp\u003eType: Relay\u003cbr\u003e Form: SPST, N.O.\u003cbr\u003e Rating: 1 amp @ 30 VAC\u003cbr\u003e OF1, OF2\u003cbr\u003e Type: Relay\u003cbr\u003e Form: SPST, N.O.\u003cbr\u003e Rating: 1\/2 HP @ 240 VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTime Delays\u003c\/strong\u003e\u003cbr\u003e Anti-Short Cycle Delay: 5 minutes\u003cbr\u003e Defrost Time: Fixed 10 minutes + 5%\u003cbr\u003e Interval Time Between Defrosts: Pin-selectable 30\/50\/90 minutes\u003cbr\u003e Test Time: Short across test terminals reduces test time 256x\u003cbr\u003e Power on Reset Time: 500ms\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471682936906,"sku":"ICM321","price":65.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/3171__12090.1487178002.1280.1280.jpg?v=1720527977"},{"product_id":"icm322-defrost-control-circuit-board-carrier-ceso130024-00","title":"ICM322 Defrost Control Circuit Board Carrier CESO130024-00","description":"\u003cp\u003eDescription:\u003cbr\u003eDefrost Control - replacement for Carrier CES0130024-00 controls\u003cbr\u003e\u003cbr\u003eSpecifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 18-30 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Relay Output:\u003c\/li\u003e\n\u003cli\u003e- N.O.: 20 amps\u003c\/li\u003e\n\u003cli\u003e- N.C.: 10 amps\u003c\/li\u003e\n\u003cli\u003eDefrost Time: Fixed 10 minutes\u003c\/li\u003e\n\u003cli\u003eInterval Time Between Defrosts: Pin-selectable 30\/50\/90 min\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003eWeight\/Dimensions:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eWeight: 0.2\u003c\/li\u003e\n\u003cli\u003eHeight: 1.32\u003c\/li\u003e\n\u003cli\u003eWidth: 3.5\u003c\/li\u003e\n\u003cli\u003eLength: 5.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures: \u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLow cost, time and temperature defrost\u003c\/li\u003e\n\u003cli\u003eTime and temperature terminate\u003c\/li\u003e\n\u003cli\u003eTest pins reduce test time by 256X\u003c\/li\u003e\n\u003cli\u003eHigh power output, outdoor fan (1\/2 HP fan @ 240 VAC)\u003c\/li\u003e\n\u003cli\u003eStrip heat, reversing valve outputs (24 VAC, 1 amp)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471683166282,"sku":"ICM322","price":42.42,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/69401__83104.1504659202.1280.1280.jpg?v=1720527979"},{"product_id":"icm323-defrost-control-circuit-board-icp-controls-html","title":"ICM323 Defrost Control Circuit Board ICP Controls","description":"\u003cp\u003eDefrost Control - replacement for ICP control with heat active (B) reversing valve\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSame as ICM304 but for heat active reversing valve\u003c\/li\u003e\n\u003cli\u003eSensor input for defrost terminate\u003c\/li\u003e\n\u003cli\u003eTime and temperature terminate\u003c\/li\u003e\n\u003cli\u003eIntegral short cycle protection\u003c\/li\u003e\n\u003cli\u003eY input tracks compressor run times\u003c\/li\u003e\n\u003cli\u003eHeat active reversing valve\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 18 to 30 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eStrip Heat \/ reversing Valve Outputs: 24 VAC, 1 amp\u003c\/li\u003e\n\u003cli\u003eDefrost Time: Fixed 10 minutes\u003c\/li\u003e\n\u003cli\u003eInterval Time Between Defrosts: Pin-selectable 30\/60\/90 min \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471683428426,"sku":"ICM323","price":76.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/13979933__72308.1504773856.1280.1280.jpg?v=1720527981"},{"product_id":"icm301-heat-pump-defrost-timer-html","title":"ICM301 Heat Pump Defrost Timer","description":"\u003cp\u003eICM301 Heat Pump Defrost Timer\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eUltra low cost \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eSimple time and temperature control \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eMust have external relays for fan reversing valve and auxiliary heat \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-size: medium;\"\u003eHigh installed base\u003c\/span\u003e\u003c\/span\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eInput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-size: medium;\"\u003e Voltage: 18 to 30 VAC\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-size: medium;\"\u003eType: Relay\u003cbr\u003eForm: SPST, N.O.\u003cbr\u003eRating: 1 amp\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eTime Delays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eDefrost Time: Fixed 10 minutes \u003cspan style=\"text-decoration: underline;\"\u003e+\u003c\/span\u003e 5%\u003cbr\u003eInterval Time Between Defrosts: Pin-selectable 30\/60\/90 min\u003cbr\u003ePower on Reset Time: 500ms\u003cbr\u003eTest Time: Short across test terminals reduces test time 256x\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471683657802,"sku":"ICM33","price":29.52,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380753__09712.1484844170.1280.1280.jpg?v=1720527979"},{"product_id":"icm307-heat-pump-defrost-timer","title":"ICM307 Heat Pump Defrost Timer","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eICM307 Heat Pump Defrost Timer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eInput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003eVoltage: 18 to 30 Vac\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003eCompressor Contacts\u003cbr\u003eType: Triac\u003cbr\u003eRating: 1 amp \u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003eDefrost Relay\u003cbr\u003eType: Triac\u003cbr\u003eRating: 1 amp\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eTime Delays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: large;\"\u003eAnti-Short Cycle Delay: 3 minutes\u003cbr\u003eDefrost Time: Fixed 10 minutes \u003cspan style=\"text-decoration: underline;\"\u003e+\u003c\/span\u003e 5%\u003cbr\u003eInterval Time Between Defrosts: Pin-selectable 30\/60\/90 minutes\u003cbr\u003eTest Time: Short across test terminals reduces test time 256x\u003cbr\u003ePower on Reset Time: 500ms\u003c\/span\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471685001290,"sku":"ICM36","price":38.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380755__99235.1484846253.1280.1280.jpg?v=1720527988"},{"product_id":"icm316-trane-heat-pump-defrost-timer-html","title":"ICM316 Trane Heat Pump Defrost Timer","description":"\u003cp\u003eICM316 Trane Heat Pump Defrost Timer\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eInput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eVoltage: 18 to 30 Vac\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003ePower Consumption: 1 watt max.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eOutput\u003cbr\u003eO, X2\u003c\/strong\u003eType: Relay\u003cbr\u003eForm: DPST, N.O\u003cbr\u003eRating: 1 amp @ 30 VAC \u003cstrong style=\"font-weight: 400;\"\u003eODF \u003c\/strong\u003eType: Relay\u003cbr\u003eForm: SPDT, N.O.\u003cbr\u003eRating: 1 amp @ 230 VAC \u003cstrong style=\"font-weight: 400;\"\u003eEDR \u003c\/strong\u003eType: Relay\u003cbr\u003eForm: DPDT, N.O.\u003cbr\u003eRating: 1 amp @ 30 VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eTime Delays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman'; font-size: medium;\"\u003eDefrost Time: Fixed 10 minutes \u003cspan style=\"text-decoration: underline;\"\u003e+\u003c\/span\u003e 5%\u003cbr\u003eInterval Time Between Defrosts: Pin-selectable 50\/70\/90 minutes\u003cbr\u003eTest Time: Short across test terminals reduces test time 256x\u003cbr\u003ePower on Reset Time: 500ms\u003c\/span\u003e\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471686082634,"sku":"ICM38","price":57.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2628790__64745.1487178004.1280.1280.jpg?v=1720527997"},{"product_id":"white-rodgers-47d01u-843-universal-heat-pump-defrost-control-html","title":"White Rodgers 47D01U-843 Universal Heat Pump Defrost Control","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eWhite Rodgers 47D01U-843 Universal Heat Pump Defrost Control\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eReplaces virtually all single stage defrost controls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSelectable demand or timed defrost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eUniversal mounting with rotating display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003ePreconfigured for major OEM brands\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eIntegrated indoor thermostat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eAccess set up and diagnostic menus from any orientation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eBrown out and short cycle protection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Copeland Comfort Control LP","offers":[{"title":"Default Title","offer_id":41472442892362,"sku":"47D01U843 WHI","price":88.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/47D01U843_WHI__85642.1575720025.1280.1280.jpg?v=1720539071"},{"product_id":"defrost-control-board-comfort-alert-html","title":"Defrost Control Board Comfort Alert","description":"\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eRheem 47-102090-06 Defrost Control Board Comfort Alert\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003eUsed With:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eRPNL47-102090-06\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eRPNL47-102090-06\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472442990666,"sku":"4710209006 RHE","price":154.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/4710209006_RHE__11240.1575613786.1280.1280.jpg?v=1720539073"},{"product_id":"honeywell-db7110u1000-universal-heat-pump-defrost-control-html","title":"Honeywell DB7110U1000 Universal Heat Pump Defrost Control","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eHoneywell DB7110U1000 Universal Heat Pump Defrost Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"overview\"\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eUniversal Defrost Control for Single Stage On\/Off Heat Pumps. It provides control of the outdoor equipment; compressor contactor, reversing valve, and outdoor fan in response to thermostat requests and air and coil temperatures. It also controls the indoor auxiliary heat source that is used during defrost operations and often as a second stage of heat. A defrost cycle is triggered based on outdoor air and outdoor coil temperatures that are measured using included temperature sensors.\u003c\/span\u003e\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"specs\"\u003e\n\u003ch2\u003e\u003cspan style=\"font-size: large;\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eApplication\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSingle Stage Heat Pumps\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eIncludes\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAir temperature sensor with 2 pin connector; Coil temperature sensor with 3 pin connector; Wire leads; Wire nuts; Mounting screws\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eComments\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAll terminals except FAN-IN and FAN-OUT are NEC Class 2 low voltage; FAN-IN and FAN-OUT are line voltage.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eItem Type\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eProduct\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMounting\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAny Orientation, but recommended to mount so display is easily readable\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eElectrical Ratings\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eMaximum Input Current: 200 mA; Compressor Contactor: 1A @ 24 Vac; Aux Heat: 1A @ 24 Vac; Reversing Valve: 1A @ 24 Vac; Outdoor Fan: 1\/2 HP motor, 5A full load, 30A locked rotor, 240 Vac.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eFrequency\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e60 Hz\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eStages\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSingle Stage On\/Off\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eElectrical Connections\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e1\/4 in. quick connect\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperating Humidity Range (% RH)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eLess than 95% RH, non-condensing\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e24 Vac\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperating Temperature Range (F)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e-40 F to 150 F\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eLEDs\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSystem LED, Fauult LED\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eAmbient Temperature Range (F)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eCoil Enable: 30 F to 36 F; Termination Temperature: 50 F to 100 F; Auxiliary Lockout Temp: 0 F to 40 F; Compressor Lockout Temp: -10 F to 40 F\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eDisplay\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e4 character 7 segment display for Menu and Settings\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperation\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAll outputs rated for 100,000 operations\u003c\/span\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41472517668938,"sku":"DB7110U1000 HON","price":116.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/DB7110U1000__25337.1605043979.1280.1280.jpg?v=1720540015"},{"product_id":"rheem-ruud-47-102684-83-defrost-control-circuit-board-html","title":"Rheem Ruud 47-102684-83 Defrost Control Circuit Board","description":"\u003cp\u003e\u003cspan\u003eRheem Ruud 47-102684-83 Defrost Control Circuit Board\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eReplaces: 47-21517-88, 47-21517-11, 47-21517-12, 47-21517-22, 47-21517-14, 47-21517-16, 47-21517-17, 47-21517-18, 47-21517-85.\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472569114698,"sku":"RHEE49","price":70.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/47-102684-83__00219.1647072307.1280.1280.jpg?v=1720540557"}],"url":"https:\/\/c38b33-2.myshopify.com\/collections\/defrost-controls.oembed","provider":"Climatedoctors","version":"1.0","type":"link"}