{"title":"Fan Controls","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"replacement-fan-control-center-relay-90-113-120v-html","title":"Replacement Fan Control Center Relay 90-113 120V","description":"\u003cp\u003eFan Control Center Primary Voltage 120 Volts Secondary Voltage 24 Volts Power Rating 3\/4 HP Power Rating @ 120 VAC 3\/4 HP Power Rating @ 208 to 240 VAC 3\/4 HP Full Load Current @ 120 VAC 13.8 Amps Full Load Current @ 208 VAC 6.9 Amps Full Load Current @ 240 VAC 6.9 Amps Locked Rotor Current @ 120 VAC 82.8 Amps Locked Rotor Current @ 208 VAC 41.4 Amps Locked Rotor Current @ 240 VAC 41.4 Amps Switch Action SPDT\u003cbr\u003e\u003cbr\u003e This is a replacement part to the OEM Honeywell part number R823A1052.\u003c\/p\u003e","brand":"Diversitech","offers":[{"title":"Default Title","offer_id":41471580536906,"sku":"FANC1","price":25.35,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380638__90725.1522165548.1280.1280.jpg?v=1720526949"},{"product_id":"honeywell-st9120u1011-control-circuit-board-fan-timer-html","title":"Honeywell ST9120U1011 Control Circuit Board Fan Timer","description":"\u003cp\u003e\u003cspan id=\"ProductContent_lblProductDescription\" class=\"HoneywellECCProductCatalogCategoryHeaderDescription\" style=\"display: inline-block; width: 400px;\"\u003e Honeywell ST9120U1011 Universal Electronic Fan Timer \u003cspan id=\"ProductContent_lblProductDescription0\" class=\"HoneywellECCProductCatalogCategoryHeaderDescription\" style=\"display: inline-block;\"\u003e (Replaces ST9120U1003) \u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial; font-size: small;\"\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cspan style=\"font-family: Calibri;\"\u003e\u003cspan style=\"color: #444444; mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Arial; font-size: small;\"\u003e\u003cstrong\u003eReplaces Old Honeywell Board #s: \u003c\/strong\u003eST9101A1006, ST9101A1014, ST9101A1022, ST9120A1006, ST9120A2004, ST9120B1005, ST9120C1012, ST9120C1020, ST9120C2002, ST9120C2010, ST9120C2028, ST9120C3000, ST9120C3018, ST9120C4008, ST9120C4016, ST9120C4040, ST9120C4057, ST9120C5005, ST9120C5013, ST9120D3009, ST9120G2008, ST9120G2016, ST9120D2024, ST9120G2032, ST9120G4004, ST9120G4012, ST9120G4038, ST9120U1003, ST9141A1002, ST9141A1028, ST9141B1001, ST9150A1003, ST9150B2000, ST9150B2018, ST9150B2026, ST9150B2034, ST9160A1002, ST9160B1001, ST9160B1019, ST9160B1027, ST9160B1035, ST9160B1043, ST9160B1050, ST9160B1068, ST9160B1076, ST9160B1084, ST9160C1000, ST9160C1018\u003c\/span\u003e\u003c\/p\u003e\u003cdiv id=\"ProductContent_pnlFeatures\"\u003e\u003cdiv id=\"ProductFeature\" class=\"HoneywellECCParametricSearchSection\"\u003e\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cspan id=\"ProductContent_lblFeaturesTitle\" class=\"HoneywellECCSubTitle\"\u003e Features\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cspan id=\"ProductContent_lblFeatures\"\u003e\u003cbr\u003eCentral appliance wiring point simplifies appliance assembly and service. \u003cbr\u003eFixed or field-adjustable heat fan on delay; field adjustable heat fan off delay.\u003c\/span\u003e\u003cp\u003e\u003c\/p\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"ProductSpecification\" class=\"HoneywellECCParametricSearchSection\"\u003e\u003ctable id=\"Table\" style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan id=\"ProductContent_lblProductSpecTitle\" class=\"HoneywellECCSubTitle\"\u003e Product Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd id=\"Separator5\" class=\"HoneywellECCMainContentSectionSeparator\" colspan=\"2\"\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl00_lblDisplayName\"\u003e Description\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl00_lblValue\"\u003e Universal Electronic Fan Timer with adjustable heat fan on, heat fan off, cool fan on, and cool fan off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl01_lblDisplayName\"\u003e Application\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl01_lblValue\"\u003e Integrates control of combustion blower and circulating fan operations for a gas warm air appliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl02_lblDisplayName\"\u003e Electrical Ratings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl02_lblValue\"\u003e18 to 30 Vac\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl03_lblDisplayName\"\u003e Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl03_lblValue\"\u003e50 Hz; 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl04_lblDisplayName\"\u003e Heat Fan On Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl04_lblValue\"\u003eadj. 30, 60 sec (set at 30 sec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl05_lblDisplayName\"\u003e Heat Fan Off Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl05_lblValue\"\u003eadj. 60, 120, 150, 180 sec (set at 120 sec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl06_lblDisplayName\"\u003e Cool Fan On Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl06_lblValue\"\u003eadj. 4, 30 sec (set at 4 sec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl07_lblDisplayName\"\u003e Cool Fan Off Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl07_lblValue\"\u003eadj. 30, 60 sec (set at 30 sec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl08_lblDisplayName\"\u003e Temperature Range, Ambient (F)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl08_lblValue\"\u003e-40 F to +175 F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl09_lblDisplayName\"\u003e Temperature Range, Ambient (C)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl09_lblValue\"\u003e-40 C to +79 C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl10_lblDisplayName\"\u003e Approvals, Underwriters Laboratories Inc\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl10_lblValue\"\u003eListed: Report MP466\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl11_lblDisplayName\"\u003e Approvals, Canadian Standards Association\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl11_lblValue\"\u003e Certified: File No. LR95329-17\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowHot\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cstrong\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl12_lblDisplayName\"\u003e Replaces\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cstrong\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl12_lblValue\"\u003eall ST9101's, all ST9120's, all ST9141's, and all ST9160's\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\u003ctr class=\"HoneywellECCDataRowNormal\"\u003e\n\u003ctd width=\"35%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl13_lblDisplayName\"\u003e Tradeline Value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"65%\"\u003e\u003cspan id=\"ProductContent_ProductSpecsRepeater_ctl13_lblValue\"\u003e Universal Tradeline\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471625265226,"sku":"HONE309","price":157.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/5274__15881.1505949357.1280.1280.jpg?v=1720527512"},{"product_id":"icm271-carrier-bryant-circuit-control-board-hh84aa020-html","title":"ICM271 Carrier Bryant Circuit Control Board HH84AA020","description":"\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eInputVoltage:18-30 VAC\u003cbr\u003eFrequency: 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eContact Ratings\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eNormally Open: 20 amps\u003cbr\u003eNormally Closed: 10 amps\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eFixed Time Delays\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eON: 75 seconds\u003cbr\u003eOFF: 105 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Times New Roman';\"\u003eReplaces: CES0110017, CES0110018, 302075-302, 302075-3 , 302075-304, 302075-352, 302075-354, P771-7002, HH84AA010, HH84AA011, HH84AA012, HH84AA013, HH84AA020, HH84AA050\u003c\/span\u003e\u003cbr\u003eRobertshaw: 695-100\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471667667018,"sku":"ICM22","price":88.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1199756__14837.1484848982.1280.1280.jpg?v=1720527888"},{"product_id":"icm253-post-purge-fan-blower-control-delay-html","title":"ICM253 Post Purge Fan Blower Control Delay","description":"\u003cp\u003eSpecifications\u003cbr\u003e\u003cbr\u003eInput Voltage: 18-30 VAC\u003cbr\u003eFrequency: 50\/60 Hz\u003cbr\u003e\u003cbr\u003eOutput 1 amp maximum\u003cbr\u003e40 ma minimum\u003cbr\u003e10 amp in rush\u003cbr\u003e\u003cbr\u003eTime Delays Adjustable\u003cbr\u003eOff: 12-390 seconds\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471667961930,"sku":"ICM23","price":27.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380729__21856.1484841583.1280.1280.jpg?v=1720527882"},{"product_id":"icm251-fan-control-delay-timer","title":"ICM251 Fan Control Delay Timer","description":"\u003cfont size=\"3\" face=\"times new roman,times,serif\"\u003eSpecifications\u003cbr\u003e\u003cbr\u003e Input\u003cbr\u003e Voltage: 18-30 VAC\u003cbr\u003e Frequency: 50\/60 Hz\u003cbr\u003e\u003cbr\u003e Output\u003cbr\u003e N.O.: 20 amps @ 240 VAC\u003cbr\u003e N.C.: 10 amps @ 240 VAC\u003cbr\u003e\u003cbr\u003e Time Delays Adjustable\u003cbr\u003e On: 1-180 seconds\u003cbr\u003e Off: 12-390 seconds\u003c\/font\u003e\u003cfont size=\"3\" face=\"times new roman,times,serif\"\u003eDrives fan directly \u003c\/font\u003e\u003cul\u003e\n\u003cli\u003e\u003cfont size=\"3\" face=\"times new roman,times,serif\"\u003eHigh power, relay output \u003c\/font\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cfont size=\"3\" face=\"times new roman,times,serif\"\u003eDual function fan delay timer \u003c\/font\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cfont size=\"3\" face=\"times new roman,times,serif\"\u003eControls the circulating fan in heat pump, A\/C and forced air systems \u003c\/font\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cfont size=\"3\" face=\"times new roman,times,serif\"\u003eOff delay controls fan relay to purge ducts of residual air at the end of the heating\/cooling cycle \u003c\/font\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eÂ \u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471668813898,"sku":"ICM251","price":27.12,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380728__32158.1484841580.1280.1280.jpg?v=1720527888"},{"product_id":"icm277-fan-blower-control-board-goodman-b1370735s-html","title":"ICM277 Fan Blower Control Board Goodman B1370735S","description":"\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003eDescription:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003eB1370735 is an genuine Goodman replacement fan control center. This fan control module is used in many Goodman, Amana, Janitrol air conditioning, air handlers, and package units. It also replaces obsolete fan control part number B13707-35S, B1370735S, ICM277C, 35501558.\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003eFan Blower Control - replacement for Goodman B1370735S, PCBFM131S control boards\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; text-decoration-line: underline; vertical-align: baseline; white-space: pre-wrap;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003eInput: Voltage - 18-30 VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003eContact Ratings:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003e- N.O.: 20 amps\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003e- N.C.: 10 amps\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; text-decoration-line: underline; vertical-align: baseline; white-space: pre-wrap;\"\u003eTime Delays:\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003e- Blower ON: 7 seconds fixed\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; vertical-align: baseline; white-space: pre-wrap;\"\u003e- Blower OFF: 65 seconds fixed\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; font-family: Verdana; text-decoration-line: underline; vertical-align: baseline; white-space: pre-wrap;\"\u003eApplications\u003c\/span\u003e\u003c\/p\u003e\u003cul style=\"margin-top: 0pt; margin-bottom: 0pt;\"\u003e\n\u003cli style=\"list-style-type: disc; font-size: 11pt; font-family: Verdana; vertical-align: baseline;\" dir=\"ltr\"\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; vertical-align: baseline; white-space: pre-wrap;\"\u003eMicroprocessor-based fan blower control\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: disc; font-size: 11pt; font-family: Verdana; vertical-align: baseline;\" dir=\"ltr\"\u003e\u003cp style=\"line-height: 1.38; margin-top: 0pt; margin-bottom: 0pt;\" dir=\"ltr\"\u003e\u003cspan style=\"font-size: 11pt; vertical-align: baseline; white-space: pre-wrap;\"\u003eFor circulating fan in heat pump, A\/C and forced air systems\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471669207114,"sku":"ICM254","price":67.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/14016101__29782.1509553095.1280.1280.jpg?v=1720527890"},{"product_id":"icm255-fan-blower-control-board-html","title":"ICM255 Fan Blower Control Board","description":"\u003cp\u003e\u003c\/p\u003e\u003ch3 align=\"left\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cp align=\"left\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eInput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"font-weight: bold;\" align=\"left\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eVoltage:18-30 VAC\u003cbr\u003eFrequency: 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"font-weight: bold;\" align=\"left\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"font-weight: bold;\" align=\"left\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eNormally Open: 20 amps @ 240 VAC\u003cbr\u003eNormally Closed: 20 amps @ 240 VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"font-weight: bold;\" align=\"left\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cstrong style=\"font-weight: 400;\"\u003eFixed Time Delays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"font-weight: bold;\" align=\"left\"\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eON: 1 second\u003cbr\u003eOFF: 60 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cdiv align=\"left\"\u003e\n\u003cspan style=\"font-weight: bold; font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cspan style=\"font-family: arial;\"\u003e\u003cem\u003e\u003cspan style=\"color: #000000;\"\u003eReplaces: 42-ICM255, 42-22515-01, 42-22515-02, 42-22515-03, 42-22515-04, \u003c\/span\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: bold; color: #000000; font-size: medium;\"\u003e\u003cspan style=\"font-family: arial;\"\u003e\u003cem\u003eBard 8201-056, Mars 32393, ICM: HBOR24A9X60, Snyder-General 1395336, Watsco 5893, Rheem 42-22515-01, Rheem 42-22515-02, Rheem 42-22515-03 and Robertshaw 100-368, \u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e1005-83-100, \u003c\/em\u003e\u003cdiv style=\"font-weight: bold; display: inline !important;\" align=\"left\"\u003e\u003cspan style=\"color: #000000; font-size: medium;\"\u003e\u003cspan style=\"font-family: arial;\"\u003e\u003cem\u003e100-376, 100-368-0.1 Trane: TMR00165\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471669665866,"sku":"ICM27","price":23.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380730__84037.1484844165.1280.1280.jpg?v=1720527889"},{"product_id":"icm273-fan-blower-control-circuit-board","title":"ICM273 Fan Blower Control Circuit Board","description":"\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eSpecifications\u003cbr\u003e\u003cbr\u003e Input\u003cbr\u003e Voltage:18-30 VAC\u003cbr\u003e Frequency: 50\/60 Hz\u003cbr\u003e\u003cbr\u003e Output\u003cbr\u003e 2 amps @ 240 VAC\u003cbr\u003e\u003cbr\u003e Time Delay Fixes\u003cbr\u003e 60 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eSolid state output \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eSilent operation, \"no clicking\" \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eControls the circulating fan in heat pump A\/C and forced air systems \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eOFF delay purges ducts of residual air \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471669698634,"sku":"ICM273","price":36.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380733__49700.1484844163.1280.1280.jpg?v=1720527891"},{"product_id":"icm274-fan-blower-control-circuit-board","title":"ICM274 Fan Blower Control Circuit Board","description":"\u003cp\u003eICM 274 Fan Blower Control Board\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMicroprocessor-based fan blower control. \u003c\/li\u003e\n\u003cli\u003eBuilt in humidity relay\u003c\/li\u003e\n\u003cli\u003eManually adjustable post-purge off delay from 60-240 Seconds \u003c\/li\u003e\n\u003cli\u003eElectronic air cleaner output\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eÂ \u003c\/p\u003e\u003cul\u003e\u003cli\u003eVoltage: 18-30 VAC\u003cbr\u003e   Outputs:\u003cbr\u003e   -Y out: 1.5 Amps\u003cbr\u003e   -Fan: 2 Amps\u003cbr\u003e   -Electric Heat Relay: 30 Amps@ 240 VAC\u003cbr\u003e   Time Delay: \u003cbr\u003e   -Blower off Delay: 60 Seconds\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eReplaces: EMI 240-1764\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471669895242,"sku":"ICM274","price":43.74,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/3155__73547.1484844165.1280.1280.jpg?v=1720527893"},{"product_id":"icm275-carrier-hh84aa021-fan-blower-control-board-html","title":"ICM275 Carrier HH84AA021 Fan Blower Control Board","description":"\u003ch3\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eICM 275 Fan Blower Control \u003c\/span\u003e\u003c\/h3\u003e\u003ch3\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eVoltage:18-30 VAC\u003cbr\u003eFrequency: 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cstrong\u003eOutput \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eContact Ratings:\u003cbr\u003e20 amps @ 240 VAC on high\u003cbr\u003e10 amps @ 240 VAC on low\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003e\u003cstrong\u003eTime Delays \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eON: 60 seconds fixed \u003cbr\u003eOFF: 60-240 seconds adjustable\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-family: Helvetica, Arial, sans-serif;\"\u003eCarrier: CES0110019, HH84AA001, HH84AA003, HH84AA005, HH84AA009, HH84AA014, HH84AA015, HH84AA021\u003c\/span\u003e\u003cbr style=\"font-family: Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-family: Helvetica, Arial, sans-serif;\"\u003eRobertshaw: 695-101\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471670091850,"sku":"ICM275","price":94.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380734__26899.1484846260.1280.1280.jpg?v=1720527895"},{"product_id":"icm270-rheem-ruud-fan-blower-control-circuit-board","title":"ICM270 Rheem Ruud Fan Blower Control Circuit Board","description":"\u003cp\u003eICM270 Rheem Ruud Fan Blower Control Circuit Board\u003c\/p\u003e\u003cp\u003eReplaces:47-22827-01, 47-22827-81, 47-22827-82, 47-22828-01, 47-22828-02\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eDual function fan delay timer \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eControls the circulating fan in a heat pump, A\/C and forced air systems \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eOFF delay purges ducts of residual air \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eON delay allows air to reach the proper comfort level prior to energizing the fan \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eSpecifications\u003cbr\u003e\u003cbr\u003e Input\u003cbr\u003e Voltage:18-30 VAC\u003cbr\u003e Frequency: 50\/60 Hz\u003cbr\u003e\u003cbr\u003e Output\u003cbr\u003e Heat\/Cool Speed\u003cbr\u003e N.O.: 20 amps @ 240 VAC\u003cbr\u003e N.C.: 10 amps @ 240 VAC\u003cbr\u003e\u003cbr\u003e Time Delays Blower Off Time Adjustable\u003cbr\u003e 90,120,150,180 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e Â \u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471670288458,"sku":"ICM28","price":52.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380731__99821.1522165548.1280.1280.jpg?v=1720527897"},{"product_id":"icm286-amana-goodman-b18099-26-b1809926s-control-board","title":"ICM286 Amana\/Goodman B18099-26 B1809926S Control Board","description":"\u003cp\u003eThe ICM286 Furnace Control Board is a form, fit and functional replacement for Goodman'sÂ popular PCBBF112S or B1809926S control board. It features micro-processor based precision with a status LED for testing and easy troubleshooting.\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eControls the gas valve, inducer draft motor, circulating blower and hot surface ignitor\u003c\/li\u003e\n\u003cli\u003eMonitors system pressure and limit switches\u003c\/li\u003e\n\u003cli\u003eMicroprocessor based precision\u003c\/li\u003e\n\u003cli\u003eTwinning compatible with another ICM286 Control Board\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs aid in testing and troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecifications:\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTiming\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eInducer Pre-Purge Time: 15 Seconds\u003c\/p\u003e\u003cp\u003eHeat Blower On Delay: 30 Seconds\u003c\/p\u003e\u003cp\u003eHeat Blower Off Delays: 90\/120\/150\/180 Seconds\u003c\/p\u003e\u003cp\u003eCool Blower on Delay: 5 Seconds\u003c\/p\u003e\u003cp\u003eCool Blower Off Delay: 45 Seconds\u003c\/p\u003e\u003cp\u003eIgnitor On: 7 Seconds\u003c\/p\u003e\u003cp\u003eInducer Post Purge: 15 Sceonds\u003c\/p\u003e\u003cp\u003eTrails for Ignition: 3 (before soft lockout)\u003c\/p\u003e\u003cp\u003eAuto Reset: 60 minutes\u003c\/p\u003e\u003cp\u003eÂ \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eVoltage Range: (98-132 VAC) @ 60Hz\u003c\/p\u003e\u003cp\u003eCool Blower: 30A, 2HP, 240 VAC\u003c\/p\u003e\u003cp\u003eHeat: 20A, 240 VAC\u003c\/p\u003e\u003cp\u003eInducer Motor: 4A FLA, 8A LRA @ 120 VAC\u003c\/p\u003e\u003cp\u003eIgnitor: 10A FLA @ 120 VAC\u003c\/p\u003e\u003cp\u003eHumidifier: 5 amps @ 120 VAC\u003c\/p\u003e\u003cp\u003eElectric Air Cleaner: 5 Amps @ 120 VAC\u003c\/p\u003e\u003cp\u003eÂ \u003c\/p\u003e\u003cp\u003eReplaces:\u003c\/p\u003e\u003cp\u003eGoodman: PCBBF112S\u003c\/p\u003e\u003cp\u003eGoodman: B1809926S\u003c\/p\u003e\u003cp\u003eGoodman: 0130F00005S\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471678120010,"sku":"ICM286","price":85.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/8842__63103.1509560556.1280.1280.jpg?v=1720527943"},{"product_id":"icm287-replaces-amana-goodman-b1809904-fan-control-html","title":"ICM287 Replaces Amana\/Goodman B1809904 Fan Control","description":"\u003cp\u003eICM287 Furnace Control Board\u003c\/p\u003e\u003cp\u003eThe ICM287 control is microprocessor based using software to determine the sequence of operation and timing. The control also monitors the status of the gas valve before energizing the inducer and heat and cool blowers.\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLow cost form, fit and functional replacement board for Goodman B18099-04\u003c\/li\u003e\n\u003cli\u003eControls inducer and blower control\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based\u003c\/li\u003e\n\u003cli\u003eDesigned for 100% gas shutoff in case of ignition failure\u003c\/li\u003e\n\u003cli\u003eMonitors timing and gas valve\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs aid in testing \/ troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecifications:\u003c\/p\u003e\u003cp\u003eLine Voltage Range: 120 VAC@ 60Hz\u003c\/p\u003e\u003cp\u003eControl Voltage: 24 VAC@ 60Hz\u003c\/p\u003e\u003cp\u003eCool Blower: 30A resistive @ 120 VAC\u003c\/p\u003e\u003cp\u003eHeat Blower: 10A resistive @ 120 VAC\u003c\/p\u003e\u003cp\u003eInducer Blower: 10A resistive @ 120 VAC\u003c\/p\u003e\u003cp\u003eÂ \u003c\/p\u003e\u003cp\u003eReplaces: Goodman: B18099-04\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471678152778,"sku":"ICM287","price":127.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/8839__31702.1509549195.1280.1280.jpg?v=1720527947"},{"product_id":"icm289-lennox-48k98-furnace-ignition-control-module-html","title":"ICM289 Lennox 48K98 Furnace Ignition Control Module","description":"\u003cp\u003eICM289 Lennox Replacement Furnace Ignition Control Module\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLow cost, direct replacement board for Lennox\u003c\/li\u003e\n\u003cli\u003eControls Inducer fan motor, blower fan and monitors limit switches\u003c\/li\u003e\n\u003cli\u003eMicroprocessor based design\u003c\/li\u003e\n\u003cli\u003eFunctions with all 24 VAC thermostat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage Range: Line (98 to 132 VAC) @ 60 Hz\u003c\/li\u003e\n\u003cli\u003eCool Blower: 20A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003eHeat Blower: 20A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003eÂ Inducer Motor: 5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003eÂ Cool Blower On Delay: 1 second\u003c\/li\u003e\n\u003cli\u003eÂ Cool Blower Off Delay: 1 second\u003c\/li\u003e\n\u003cli\u003eÂ Heat Blower On Delay: 45 seconds\u003c\/li\u003e\n\u003cli\u003eÂ Heat Blower Off Delay: 90, 150, 210, 270 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eReplaces:\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"style1\"\u003eÂ \u003c\/span\u003eLennox - \u003c\/strong\u003eÂ  Replaces all BCC1, BCC2 and BCC3 circuit boards, including models LB-53622A, BCC2-\u003cbr\u003e2REV8, 35K77, 35K7701, LB-90089A, 65K29, 65K2901, LB-50709BD, LB-65126A, LB-\u003cbr\u003e89859, LB-87086A, LB-90676B, LB-87086, LB-63622AA, LB-90676A, 40L8801, 30H6701, 48K98,\u003cbr\u003e48K9801, 45K48, 45K4801, 78J61, 78J6101, 68H08.\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471678611530,"sku":"ICM289","price":181.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/3713__38291.1509477383.1280.1280.jpg?v=1720527950"},{"product_id":"icm2901-spark-gas-ignition-control-replaces-g770rja-1-html","title":"ICM2901 Spark Gas Ignition Control Replaces G770RJA-1","description":"\u003cp\u003eThe ICM2901 Spark Gas Ignition Control Replaces G770RJA-1\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIntermittent pilot gas ignition control\u003c\/li\u003e\n\u003cli\u003eFor use with intermittent pilot boilers, furnaces and other heating appliances\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based precision\u003c\/li\u003e\n\u003cli\u003eMonitors timing, trial for ignition, rollout switch, flame sensing and lockout\u003c\/li\u003e\n\u003cli\u003eRemote flame sensing\u003c\/li\u003e\n\u003cli\u003e100% lockout safety feature\u003c\/li\u003e\n\u003cli\u003eWorks with both Natural and LP gas systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecifications:\u003c\/p\u003e\u003cp\u003eControl Voltage: Line 24V (18-30 VAC), 50\/60Hz\u003c\/p\u003e\u003cp\u003eAnticipator Setting: 0.2A plus valve load @ 24VAC\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e Prepurge: None \u003cbr\u003e\u003cbr\u003e Trial for Ignition: 85 seconds\u003c\/p\u003e\u003cp\u003eFlame Failure Response Time: 0.5 seconds max.\u003c\/p\u003e\u003cp\u003eRetry: None\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eReplaces:\u003c\/p\u003e\u003cp\u003eJohnson Controls G770RJA-1,\u003cbr\u003e York 025-27762-700\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471679529034,"sku":"ICM2901","price":134.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/8847__26403.1509544058.1280.1280.jpg?v=1720527956"},{"product_id":"icm2902-ipi-gas-ignition-control-replaces-g776rgd-14-html","title":"ICM2902 IPI Gas Ignition Control replaces G776RGD-14","description":"\u003cp\u003eICM2902 IPI Gas Ignition Control\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\u003cul\u003e\n\u003cli\u003eIntermittent pilot gas ignition control\u003c\/li\u003e\n\u003cli\u003eFor use with intermittent pilot boilers, furnaces and other heating appliances\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based precision\u003c\/li\u003e\n\u003cli\u003eMonitors timing, trial for ignition, flame sensing and lockout\u003c\/li\u003e\n\u003cli\u003eRemote flame sensing\u003c\/li\u003e\n\u003cli\u003e100% lockout safety feature\u003c\/li\u003e\n\u003cli\u003eWorks with both Natural and LP gas systems\u003c\/li\u003e\n\u003cli\u003eStatus LED for fault codes to aid in troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSpecifications:\u003c\/p\u003e\u003cp\u003eControl Voltage: Line 24V (18-30 VAC), 50\/60Hz\u003c\/p\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eAnticipator Setting: 0.2A plus valve load @ 24VAC\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cdiv\u003ePrepurge: 15 seconds\u003c\/div\u003e\u003c\/div\u003e\u003cdiv\u003eTrial for Ignition: 85 seconds\u003cbr\u003e\u003cdiv\u003eLockout: 60 minutes\u003c\/div\u003e\n\u003c\/div\u003e\u003cp\u003eFlame Failure Response Time: 0.5 seconds max.\u003c\/p\u003e\u003cp\u003eLED: See product label for error codes\u003c\/p\u003e\u003cp\u003eReplaces:\u003c\/p\u003e\u003cp\u003eLennox: 30W33\u003c\/p\u003e\u003cp\u003eRobertshaw: 735L (18G91), 745 (95H04)\u003c\/p\u003e\u003cp\u003eJohnson Controls: G776 (63K2401, 41K8701, 69J3601)\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471679725642,"sku":"ICM2902","price":112.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/8848__49126.1509477383.1280.1280.jpg?v=1720527958"},{"product_id":"icm-controls-icm278-fan-blower-control-board-html","title":"ICM Controls ICM278 Fan Blower Control Board","description":"\u003cp\u003eReplaces Carrier HH84AA017, HH84AA018\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41471862243402,"sku":"ICM278","price":124.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2326122__97036.1484863080.1280.1280.jpg?v=1720530274"},{"product_id":"carrier-hk42fz017-icm2807-furnace-control-board-html","title":"Carrier HK42FZ017 ICM2807 Furnace Control Board","description":"\u003cdiv class=\"details-div\"\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: large;\"\u003eDETAILS:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003eThe ICM2807 is a low cost fit, form and functional replacement for the Carrier HK42FZ017 furnace control board.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eControls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eMicroprocessor-based precision\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eDesigned for 100% gas shutoff in case of ignition failure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eTwinning compatible with another ICM2807 control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eReverse polarity protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSecondary brownout voltage protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCompatible with 24 VAC standard thermostat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eContinuous Blower Speed Jumper\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLimit Switch Lockout Time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLimit Switch Lockout After Power Interruption\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSelf-Diagnostics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eProvides diagnostic\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cdiv class=\"weight-dimension-div\"\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: large;\"\u003eWEIGHT\/DIMENSIONS:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWeight: 1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eHeight: 1.5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWidth: 6.5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLength: 7\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cdiv class=\"weight-dimension-div\"\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: large;\"\u003eSPECIFICATIONS:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e– Operating: -40°F to 176°F\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e– Humidity: 5% to 95% R.H. (non-condensing) @ +55°F\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eVoltage Range: \u003c\/strong\u003eLine (98 to 132 VAC) @ 60Hz\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eIgnitor: \u003c\/strong\u003e5A @ 120 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eCool Blower: \u003c\/strong\u003e10 HP, 120 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eLow Heat: \u003c\/strong\u003e5A, 1\/2 HP, 120 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eHigh Heat: \u003c\/strong\u003e10A, 1 HP, 120 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eInducer Motor: \u003c\/strong\u003e4A, FLA-8.0 LRA @ 120 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eGas Valve: \u003c\/strong\u003e1.5A @ 30 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eEAC: \u003c\/strong\u003e1A@120 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eHumidifier: \u003c\/strong\u003e0.5A \u0026amp; 24 VAC\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"additional-content-div\"\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: large;\"\u003eREPLACES:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eCarrier:\u003c\/strong\u003e HK42FZ017\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471862276170,"sku":"ICM2807","price":338.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/3460879__54162.1484849002.1280.1280.jpg?v=1720530275"},{"product_id":"nordyne-626337r-fan-control-limit-switch-f115-30-html","title":"Nordyne 626337R Fan Control Limit Switch F115-30","description":"\u003cp\u003eREPL,FAN,CONTROL 115 F\u003c\/p\u003e","brand":"Nordyne","offers":[{"title":"Default Title","offer_id":41472098893898,"sku":"626337R","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"nortek-922016-replacement-blower-control-board-dm2f-html","title":"Nortek 922016 Replacement Blower Control Board DM2F","description":"\u003cp\u003eNortek 922016 Replacement Blower Control Board for PGC2MQ Series. DM2F. Modulating Stages\u003c\/p\u003e","brand":"Nordyne HVAC","offers":[{"title":"Default Title","offer_id":41472133660746,"sku":"922016 NOR","price":525.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/922016-3__28956.1656618944.1280.1280.jpg?v=1720535351"},{"product_id":"nordyne-920920-control-board-blower-constant-torque-html","title":"Nordyne 920920 Control Board Blower Constant Torque","description":"\u003cp\u003e\u003cspan\u003eNordyne Blower Board # 920920; Direct Cross of obsolete Nordyne 624756R\u003c\/span\u003e\u003c\/p\u003e","brand":"Nordyne HVAC","offers":[{"title":"Default Title","offer_id":41472270106698,"sku":"920920 NOR","price":69.43,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/920920-2__11404.1639620154.1280.1280.jpg?v=1720537370"},{"product_id":"rheem-47-23619-03-blower-control-board-html","title":"Rheem 47-23619-03 Blower Control Board","description":"\u003cp\u003e\u003cspan\u003eRheem 47-23619-03 Blower Control Board\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eReplaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e47-23566-82\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e47-23566-02\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e47-ICM276\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e47-23619-02\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472461733962,"sku":"472361903 RHE","price":178.18,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/472361903_RHE__41596.1578713930.1280.1280.jpg?v=1720539365"},{"product_id":"rheem-control-board-communicating-air-handler-html","title":"Rheem Control Board - Communicating Air Handler","description":"\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eRheem 47-102606-85 Control Board - Communicating Air Handler\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eOne 47-102606-05Control Board - Communicating Air Handler\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eOne 92-26177-597Instruction Sheet\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eUsed With:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eRHPL47-102606-00\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eRHPN47-102606-00\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eRHPL47-102606-01\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eRH2V47-102606-05\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eReplaces:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-102606-00\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-102606-81\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-102606-01\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-102606-05\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472485228618,"sku":"4710260685 RHE","price":124.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/4710260685_RHE__75513.1579086241.1280.1280.jpg?v=1720539391"},{"product_id":"rheem-47-100436-84j-blower-control-board-html","title":"Rheem 47-100436-84J Blower Control Board","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRheem 47-100436-84J Blower Control Board\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"form_table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth valign=\"bottom\"\u003e\u003cspan style=\"font-size: small;\"\u003eComponent:\u003c\/span\u003e\u003c\/th\u003e\n\u003cth valign=\"bottom\"\u003e\u003cspan style=\"font-size: small;\"\u003eQuantity:\u003c\/span\u003e\u003c\/th\u003e\n\u003cth valign=\"bottom\"\u003e\u003cspan style=\"font-size: small;\"\u003eDescription:\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003ca href=\"https:\/\/www.rheemparts.com\/parts\/part072006.aspx?pn=45-102645-01\" target=\"_parent\"\u003e\u003cspan style=\"color: #000000;\"\u003e45-102645-01\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eWiring Harness\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003ca href=\"https:\/\/www.rheemparts.com\/parts\/part072006.aspx?pn=47-100436-05\" target=\"_parent\"\u003e\u003cspan style=\"color: #000000;\"\u003e47-100436-05\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eControl Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003ca href=\"https:\/\/www.rheemparts.com\/parts\/part072006.aspx?pn=90-102702-01\" target=\"_parent\"\u003e\u003cspan style=\"color: #000000;\"\u003e90-102702-01\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eWiring Diagram\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003ca href=\"https:\/\/www.rheemparts.com\/parts\/part072006.aspx?pn=92-26177-566\" target=\"_parent\"\u003e\u003cspan style=\"color: #000000;\"\u003e92-26177-566\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eInstruction Sheet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472489095242,"sku":"4710043684J RHE","price":40.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/4710043684J_RHE__15886.1579159692.1280.1280.jpg?v=1720539482"},{"product_id":"rheem-control-board-html","title":"Rheem Control Board","description":"\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eRheem 47-100436-05 Control Board\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eReplaces:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e47-102077-04\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e47-100436-01\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eUsed with:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eRHSA\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSL\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSHSL\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAHSA\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eEH1P\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRH1P\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRH1P\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHAL\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSH1P\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSH1P\u003c\/span\u003e\u003cspan\u003e47-100436-05\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSA\u003c\/span\u003e\u003cspan\u003e47-100436-84A\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSL\u003c\/span\u003e\u003cspan\u003e47-100436-84A\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAHSA\u003c\/span\u003e\u003cspan\u003e47-100436-84A\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSA\u003c\/span\u003e\u003cspan\u003e47-100436-84D\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSL\u003c\/span\u003e\u003cspan\u003e47-100436-84D\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSA\u003c\/span\u003e\u003cspan\u003e47-100436-84J\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRHSL\u003c\/span\u003e\u003cspan\u003e47-100436-84J\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAHSA\u003c\/span\u003e\u003cspan\u003e47-100436-84J\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRF1P\u003c\/span\u003e\u003cspan\u003e47-102077-04\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472489160778,"sku":"4710043605 RHE","price":29.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/4710043605_RHE__30667.1579135278.1280.1280.jpg?v=1720539487"},{"product_id":"rheem-fan-center-html","title":"Rheem Fan Center","description":"\u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eRheem 47-19807-04 Fan Center\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eReplaces:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-19230-01\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e8406-5519\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e8406-5531\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-19807-02\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e47-19807-01\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e8406-5529\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Ruud","offers":[{"title":"Default Title","offer_id":41472541327434,"sku":"471980704 RHE","price":44.58,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/471980704_RHE__01555.1616609411.1280.1280.jpg?v=1720540254"},{"product_id":"rheem-ruud-47-22445-01-fan-control-circuit-board-hvac-html","title":"Rheem Ruud 47-22445-01 Fan Control Circuit Board HVAC","description":"\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eRheem Ruud 47-22445-01 Fan Control Circuit Board Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eFan Time On: 30,60,105 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eFan Time Off: 90,120,150 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eCoil Voltage: 24 V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003ePrimary Voltage: 120\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eReplaces: 47-22577-01, 47-22445-02, 4722481-01, 47-22445-01, 47-22481-81, 8404-5600, 8404-5593\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472558563402,"sku":"472244501 RHE","price":182.24,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/472244501_RHE__94099.1628217355.1280.1280.jpg?v=1720540444"},{"product_id":"rheem-rgedzs150-62-102860-06-control-board-non-ddc-html","title":"Rheem RGEDZS150 62-102860-06 Control Board NON DDC","description":"\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41472560726090,"sku":"6210286006 RHE","price":174.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/parts.rheem__22599.1646863873.1280.1280.jpg?v=1720540467"},{"product_id":"icm-controls-icm6202-fan-control-html","title":"ICM Controls ICM6202 Fan Control","description":"\u003cul\u003e\n\u003cli\u003eAbility to operate line voltage 3-speed fan motor with low voltage controls\u003c\/li\u003e\n\u003cli\u003eCompatible with 4 pipe and 2 pipe systems with auto-changeover\u003c\/li\u003e\n\u003cli\u003e20 VA 24VAC power supply\u003c\/li\u003e\n\u003cli\u003eSuitable for 1\/8 HP motors\u003c\/li\u003e\n\u003cli\u003e1\/4” Quick connect terminals\u003c\/li\u003e\n\u003cli\u003eMounts with standard 3” track\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":41472630227018,"sku":"ICM6202","price":76.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/ICM6202__03381.1712163059.1280.1280.png?v=1720541710"}],"url":"https:\/\/c38b33-2.myshopify.com\/collections\/fan-controls.oembed","provider":"Climatedoctors","version":"1.0","type":"link"}