{"title":"Pilot Retrofit Systems","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"honeywell-y8610u4001-y-pack-pilot-conversion-kit-html","title":"Honeywell Y8610U4001 Y-Pack Pilot Conversion Kit","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eHoneywell Y8610U4001 Y-Pack Pilot Conversion Kit\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eOverview:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntermittent Pilot Retrofit Kits save energy by converting atmospheric standing pilot systems to intermittent pilot.  Typical applications are gas-fired atmospheric furnaces, boilers and heating appliances.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"outline: none;\"\u003eUse with natural or LP gas\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eIncludes gas valve, ignition module, pilot burner hardware, ignition cable, and wiring harness\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eProvides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eIgnition trail\/delay sequence is repeated until the appliance lights or call for heat is removed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e Product Specifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIncludes: \u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eVR8204A2142 valve (1\/2 x 1\/2; 3.5\" WC setting; 150 kBtu\/hr at 1\" p.d.)\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eElectrical Ratings: 24 Vac\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eFrequency: 60 Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eFlame Failure Response Time: 2.0 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003ePrePurge: 0 or 30 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eAmbient Temperature Range: -40F to +165F\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eIgnition System Type: Intermittent Pilot\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eIgnition Sequence: \u003c\/span\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eContinuous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eTypical Gas Control: VR8204, VR8304\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eType of Gas: Natural or LP\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eFlame Sense: Single Rod or Two Rods\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eIgnition Source: \u003c\/span\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eInternal high voltage spark generator\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eIgnition Trials To Lockout: continuous retry\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eLockout Timing: 15 or 90 seconds\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eMaximum Valve Load @ 23 Vac (Amps): 1A Pilot, 2A Main @ 24Vac\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #666666; font-family: Arial, Verdana, Helvetica, sans-serif; background-color: #ffffff;\"\u003eTypical Ignition Hardware: Q345, Q3451\u003c\/span\u003e\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471622479946,"sku":"HONE263","price":305.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/7914079__71948.1509661659.1280.1280.jpg?v=1720527469"},{"product_id":"robertshaw-712-017-intermittent-pilot-ignition-system-html","title":"Robertshaw 712-017 Intermittent Pilot Ignition System","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eRobertshaw 712-017 Intermittent Pilot Ignition System\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eThe Uni-Line 712 series pilot ignition system features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 series pilot ignition system features quick and easy installation with complete in-depth instructions and trouble shooting information\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eIncludes:\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e720-070 1\/2\" Inlet X 3\/4\" Outlet Gas Valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e780-715 non-lockout Ignition Control\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eNatural Gas Only -Nonlockout. (Pressure regulator is factory-set at 3.5\" W.C. 200,000 Btu Max.)\u003c\/span\u003e\u003c\/p\u003e","brand":"Robertshaw Controls \/ Bluehawk","offers":[{"title":"Default Title","offer_id":41471811420234,"sku":"ROBE6","price":232.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/3313__44446.1484845905.1280.1280.jpg?v=1720529140"}],"url":"https:\/\/c38b33-2.myshopify.com\/collections\/pilot-retrofit-systems.oembed","provider":"Climatedoctors","version":"1.0","type":"link"}