{"title":"Zone Valves","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"honeywell-v4044a1019-zone-valve-1-2-3-way-120-volt-html","title":"Honeywell V4044A1019 Zone Valve 1\/2\" 3 way 120 volt","description":"\u003cp\u003e120V 1\/2 in. Sweat Connection Line Voltage Motorized Zone Valves with 4 Cv capacity. ON-OFF and diverting line voltage valves consist of an actuator motor and valve assembly for controlling the flow of hot or chilled water, and some models for steam. \u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eManual opener for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/li\u003e\n\u003cli\u003eAll models may be installed without disassembling the valve.\u003c\/li\u003e\n\u003cli\u003eCompact construction for easy installation.\u003c\/li\u003e\n\u003cli\u003eComplete powerhead may be removed or replaced without breaking line connections or draining the system.\u003c\/li\u003e\n\u003cli\u003eMotor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003cli\u003eSuitable for heating and cooling applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOverview\u003cbr\u003eOn-off and diverting line voltage valves consist of an actuator motor and valve assembly for controlling the flow of hot or chilled water.\u003cbr\u003eFeatures\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eManual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/li\u003e\n\u003cli\u003eAll models may be installed without disassembling the valve.\u003c\/li\u003e\n\u003cli\u003eCompact construction for easy installation.\u003c\/li\u003e\n\u003cli\u003eComplete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.\u003c\/li\u003e\n\u003cli\u003eMotor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003cli\u003eSuitable for heating and cooling applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003ch2 style=\"outline: none; margin: 0px 0px 2px; border-bottom: none; line-height: 20px; padding: 0px; background-color: #ffffff; font-size: 13px !important;\"\u003eProduct Specifications\u003c\/h2\u003e\u003cdl style=\"outline: none; font-size: 12px; overflow: hidden; margin: 0px; background-color: #ffffff;\"\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eApplication\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eHydronic Control\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDimensions (in.)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e4 5\/8 in. high x 3 1\/2 in. wide x 2 3\/8 in. deep\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDimensions (mm)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e117 mm high x 90 mm wide x 60 mm deep\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eComments\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eValve designed for cycling (not constantly powered on) applications. Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFrequency\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e60 Hz\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eApprovals, Underwriters Laboratories Inc.\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eUL Listed: File MH11826\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eOperating Humidity Range (% RH)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e5 to 95% relative humidity, non-condensing.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eVoltage\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e120 Vac; Power Consumption--9.6 VA\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eTiming\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eNominal Open--30 sec\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAmbient Temperature Range (F)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e125 F Maximum\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAmbient Temperature Range (C)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e52 C Maximum\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eConnection Type\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eSweat\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eBody Pattern\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eThree-way, Diverting\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003ePipe Size (inch)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e1\/2 in.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003ePipe Size (DN)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eDN15\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCurrent Draw\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e0.08A\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFluid Temperature (C)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e5 C to 93 C\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFluid Temperature (F)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e40 F to 200 F\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaximum Differential Pressure Ratings (Close-off) (psi)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e20 psi\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaximum Differential Pressure Ratings (Close-off) (kPa)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e138 kPa\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eElectrical Connections (in.)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e18 in. leads\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eElectrical Connections (mm)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e457 mm leads\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCapacity (Cv)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e4 Cv\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCapacity (Kv)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e3.4 Kv\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eValve Action\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eSpring Return to port A\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eValve Type\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eZone Valve\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Body)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBrass\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Seat)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBrass\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Stem)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eStainless Steel\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eActuation\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eTwo position\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDe-energized Position\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003ePort A Normally Closed\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eStatic Pressure Rating (psi)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e125 psi\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eStatic Pressure Rating (kPa)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e862 kPa\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Plug\/Ball\/Disc)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBuna-N (NBR) Rubber Ball\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Packing)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eEPDM rubber\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eManual Opener\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eYes\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471610585162,"sku":"HONE215","price":103.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/13962206__16475.1504726026.1280.1280.jpg?v=1720527348"},{"product_id":"honeywell-802360la-zone-valve-replacement-motor-html","title":"Honeywell 802360LA Zone Valve Replacement Motor","description":"\u003cp\u003eHoneywell 802360LA Replacement Motor for V4043, V4044 Zone Valves \u003c\/p\u003e\u003cp\u003eApplication: Replacement Part for V Series Zone Valves\u003c\/p\u003e\u003cp\u003eVoltage: 120V\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471624413258,"sku":"HONE291","price":42.26,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380637__53543.1512440967.1280.1280.jpg?v=1720527496"},{"product_id":"honeywell-802360ja-zone-valve-motor-html","title":"Honeywell 802360JA Zone Valve Motor","description":"\u003cp\u003eDescription: 24V, 50\/60Hz replacement motor for V8043 zone valves \u003c\/p\u003e\u003cp\u003eApplication: Replacement Part for V Series Zone Valves\u003c\/p\u003e\u003cp\u003eVoltage: 24V\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471630770250,"sku":"HONE338","price":33.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1380636__26539.1484841850.1280.1280.jpg?v=1720527590"},{"product_id":"honeywell-v8043e1079-2-way-normally-closed-1-sweat-24vac-zone-valve-html","title":"Honeywell V8043E1079 2 Way Normally Closed, 1', Sweat, 24Vac Zone Valve","description":"\u003cp\u003eTwo-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water.\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eManual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/li\u003e\n\u003cli\u003eAll models may be installed without disassembling the valve.\u003c\/li\u003e\n\u003cli\u003eCompact construction for easy installation.\u003c\/li\u003e\n\u003cli\u003eComplete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.\u003c\/li\u003e\n\u003cli\u003eActuator motor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471638077514,"sku":"HONE415","price":108.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2522517__98199.1484841934.1280.1280.jpg?v=1720527661"},{"product_id":"honeywell-v8043e1061-2-way-normally-closed-3-4-sweat-24vac-zone-valve-html","title":"Honeywell V8043E1061 2 Way Normally Closed, 3\/4', Sweat, 24Vac Zone Valve","description":"\u003cp\u003eHoneywell model V8043E1061 24V 50\/60Hz Two Position Spring Return Normally Closed Straight Through zone valve With Spst End Switch. Has 3\/4 inch copper solder connections, high capacity. Valve Opens When Energized. Controls Flow Of Hot And\/Or Cold Water W\/Manual Opener. 3\/4 wire leads. 8 Cv flow rating with 8 Psi Close-Off.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eON-OFF and two-way low voltage valve\u003c\/li\u003e\n\u003cli\u003eManual opener for valve operation on power failure\u003c\/li\u003e\n\u003cli\u003eComplete powerhead may be removed or replaced without breaking connections or draining the system\u003c\/li\u003e\n\u003cli\u003eActuator motor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003cli\u003eChilled water models available for cooling and heating applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eTwo-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. \u003c\/p\u003e\u003cdiv class=\"overview\" style=\"outline: none; background-color: #ffffff;\"\u003e\u003cp style=\"outline: none; line-height: 14px; margin: 0px; padding-bottom: 7px;\"\u003e\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"features\" style=\"outline: none; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"outline: none; margin: 0px 0px 2px; border-bottom: none; line-height: 20px; padding: 0px;\"\u003e\u003cspan style=\"font-size: medium;\"\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp style=\"outline: none; line-height: 14px; margin: 0px; padding-bottom: 7px;\"\u003e\u003c\/p\u003e\n\u003cul style=\"outline: none; margin: 0px 0px 15px; padding: 0px 0px 0px 15px;\"\u003e\n\u003cli style=\"outline: none;\"\u003eManual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eAll models may be installed without disassembling the valve.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eCompact construction for easy installation.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eComplete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eActuator motor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"outline: none; line-height: 14px; margin: 0px; padding-bottom: 7px;\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"specs\" style=\"outline: none; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"outline: none; margin: 0px 0px 2px; border-bottom: none; line-height: 20px; padding: 0px;\"\u003e\u003cspan style=\"font-size: medium;\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdl style=\"outline: none; overflow: hidden; margin: 0px;\"\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eApplication\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eHydronic Control\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDimensions (in.)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e4 in. high x 3 1\/2 in. wide x 2 3\/8 in. deep\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDimensions (mm)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e102 mm high x 89 mm wide x 60 mm deep\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eComments\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eUse this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water. Valve designed for cycling (not constantly powered on) applications.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFrequency\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e50 Hz; 60 Hz\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eApprovals, Underwriters Laboratories Inc.\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eUL Listed: File MH11826\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eOperating Humidity Range (% RH)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e5 to 95% relative humidity, non-condensing.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eVoltage\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e24 Vac; Power Consumption--7.7 VA\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eTiming\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eNominal Open--15 sec\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAmbient Temperature Range (F)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e125 F Maximum\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAmbient Temperature Range (C)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e52 C Maximum\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eConnection Type\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eSweat\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eBody Pattern\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eTwo-way, Straight-through\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003ePipe Size (inch)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e3\/4 in.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003ePipe Size (DN)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eDN20\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCurrent Draw\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e0.32A\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFluid Temperature (C)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e10 C to 93 C\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFluid Temperature (F)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e50 F to 200 F\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaximum Differential Pressure Ratings (Close-off) (psi)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e8 psi\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaximum Differential Pressure Ratings (Close-off) (kPa)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e55 kPa\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eElectrical Connections (in.)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e18 in. leads\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eElectrical Connections (mm)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e457 mm leads\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCapacity (Cv)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e8 Cv\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCapacity (Kv)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e6.9 Kv\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eValve Action\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eSpring return to close\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eValve Type\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eZone Valve\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Body)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBrass\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Seat)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBrass\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Stem)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eStainless Steel\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eEnd Switch Rating\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e50 VA pilot duty @ 24 V; 4.4 A running with 26.4 A inrush @ 120 V\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eActuation\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eTwo position\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDe-energized Position\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eNormally Closed\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAuxiliary End Switch\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eN.O. SPST\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eStatic Pressure Rating (psi)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e125 psi\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eStatic Pressure Rating (kPa)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e862 kPa\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Plug\/Ball\/Disc)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBuna-N (NBR) Rubber Ball\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Packing)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eEPDM rubber\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eManual Opener\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eYes\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471661244490,"sku":"HONE71","price":93.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2515796__19975.1512177452.1280.1280.jpg?v=1720527846"},{"product_id":"honeywell-v8043e1012-2-way-normally-closed-3-4-sweat-24vac-zone-valve-html","title":"Honeywell V8043E1012 2 Way Normally Closed, 3\/4', Sweat, 24Vac Zone Valve","description":"\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eHoneywell model V8043E1012 24V 50\/60 Hz Two Position Spring Return Normally Closed Straight Through Valve With Spst End Switch. Valve Opens When Energized. Controls Flow Of Hot And\/Or Cold Water with Manual Opener. Tradelinemodel. 3\/4 wire leads.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"content\"\u003e\u003cul style=\"list-style-type: disc; margin-left: 25px;\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eProvide 2-position, straight through control of water\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eCompact construction for easy installation, Fits under the cover of most baseboards\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eManual opener for valve operation on power failure\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eValve returns to automatic position when power is restored\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times, serif; font-size: medium;\"\u003eMotor can be replaced by removing screw, without disturbing the valve body or draining the system\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471661473866,"sku":"HONE72","price":92.64,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2515797__68563.1484844155.1280.1280.jpg?v=1720527849"},{"product_id":"white-rodgers-1300-series-1361-103-hydronic-zone-valve-html","title":"White Rodgers 1300 Series 1361-103 Hydronic Zone Valve","description":"\u003cul class=\"a-unordered-list a-vertical a-spacing-none\"\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003e1\" Zone Valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eCountry Of Origin: China\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eFrom The Brand Name: White Rodgers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eFor zoning systems up to 50 PSI\u003c\/li\u003e\n\u003cli\u003eDesigned for quiet and efficient operation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Copeland Comfort Control LP","offers":[{"title":"Default Title","offer_id":41472432898122,"sku":"1361103S1 WHI","price":174.21,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1361103S1_WHI__81893.1567803920.1280.1280.jpg?v=1720538840"},{"product_id":"white-rodgers-1300-series-1361-102-hydronic-zone-valve-html","title":"White Rodgers 1300 Series 1361-102 Hydronic Zone Valve","description":"\u003cp\u003e\u003cspan\u003e1300 Series valves for zoning systems up to 50 PSI operate quietly and efficiently providing years of reliable service\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSelf-aligning barrel-type valve stem design \u003c\/li\u003e\n\u003cli\u003eMade of a corrosion-resistant stainless steel \u003c\/li\u003e\n\u003cli\u003eMotor can be removed from valve assembly without draining system \u003c\/li\u003e\n\u003cli\u003eBuilt-in auxiliary contacts to control burner or circulator relay \u003c\/li\u003e\n\u003cli\u003eAutomatic recycling manual operator shows valve position at all times \u003c\/li\u003e\n\u003cli\u003eScrew terminal wiring panel for added convenience\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003eSize 3\/4” Tubing (I.D.) \u003c\/li\u003e\n\u003cli\u003eThermostat Type 3 - Wire \u003c\/li\u003e\n\u003cli\u003eTime Cycle Open: 45 secondsClose: 60 seconds\u003c\/li\u003e\n\u003cli\u003ePressure Maximum Differential Across Valve - 15 PSI \u003c\/li\u003e\n\u003cli\u003eMaximum Fluid Temp. 240°F(116°C) \u003c\/li\u003e\n\u003cli\u003ePressure 50 PSI (max) \u003c\/li\u003e\n\u003cli\u003eFlow Cv 23.5 (GPM @ 1 PSI drop) Equivalent to 2.5 Ft. of Tubing \u003c\/li\u003e\n\u003cli\u003eElectrical Rating 24 Vac, 1311 0.4A, 1361 0.2A, Aux Switch 2.0A \u003c\/li\u003e\n\u003cli\u003eElectrical Rating 24 Vac, 1311 0.4A, 1361 0.2A, Aux Switch 2.0A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Copeland Comfort Control LP","offers":[{"title":"Default Title","offer_id":41472433160266,"sku":"1361102S1 WHI","price":156.66,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/1361102_WHI__08420.1567804358.1280.1280.jpg?v=1720538836"},{"product_id":"honeywell-24v-3-4-in-zone-valve-pro-press-with-18-in-lead-wires-and-end-switch-html","title":"Honeywell 24V 3\/4 in. Zone Valve Pro Press with 18 in. lead wires and end switch","description":"\u003ch2\u003e\u003cspan style=\"font-size: large;\"\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\u003cdiv class=\"overview\"\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eTwo-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water.\u003c\/span\u003e\u003c\/p\u003e\u003c\/div\u003e\u003ch2\u003e\u003cspan style=\"font-size: large;\"\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\u003cdiv class=\"features\"\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eManual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eAll models may be installed without disassembling the valve.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCompact construction for easy installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eComplete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eActuator motor may be replaced without removing the valve body or draining the system\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003ch2\u003e\u003cspan style=\"font-size: large;\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\u003cdiv class=\"features\"\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eApplication\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eHydronic Control\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eDimensions (in.)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e4 in. high x 2 3\/8 in. wide x 6 25\/32 in.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eFrequency\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e50 Hz; 60 Hz\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eApprovals, Underwriters Laboratories Inc.\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eUL Listed: File MH11826\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eApprovals, Canadian Standards Association\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eCSA Certified: File 1322\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperating Humidity Range (% RH)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e5 to 95% relative humidity, non-condensing.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eVoltage\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e24 Vac; Power Consumption--7.7 VA\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eTiming\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eNominal Open--15 sec\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eAmbient Temperature Range (F)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e125 F Maximum\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eAmbient Temperature Range (C)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e52 C Maximum\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eConnection Type\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003ePro Press\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eBody Pattern\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eTwo-way, Straight-through\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003ePipe Size (inch)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e3\/4 in.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003ePipe Size (DN)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eDN20\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eCurrent Draw\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e0.32A\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eFluid Temperature (C)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e4 C to 93 C\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eFluid Temperature (F)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e40 F to 200 F\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaximum Differential Pressure Ratings (Close-off) (psi)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e20 psi\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaximum Differential Pressure Ratings (Close-off) (kPa)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e138 kPa\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eElectrical Connections (in.)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e18 in. leads\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eElectrical Connections (mm)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e457 mm leads\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eCapacity (Cv)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e3.0 Cv\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eCapacity (Kv)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e3 Kv\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eValve Action\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSpring return to close\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eValve Type\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eZone Valve\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaterials (Body)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eBrass\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaterials (Seat)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eBrass\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaterials (Stem)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eStainless Steel\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eActuation\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eTwo position\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eDe-energized Position\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eNormally Closed\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eStatic Pressure Rating (psi)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e120 PSI\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eStatic Pressure Rating (kPa)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e827 kPa\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaterials (Plug\/Ball\/Disc)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eBuna-N (NBR) Rubber Ball\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMaterials (Packing)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eEPDM rubber\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eManual Opener\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eYes\u003c\/span\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41472585498698,"sku":"V8043E1412 HON","price":120.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/V8043E1412_HON__49624.1682719543.1280.1280.jpg?v=1720540781"}],"url":"https:\/\/c38b33-2.myshopify.com\/collections\/zone-valves.oembed","provider":"Climatedoctors","version":"1.0","type":"link"}