{"product_id":"fast-stat-3000-thermostat-add-a-wire-4-wire-over-2-wire-html","title":"Fast Stat 3000 Thermostat Add A Wire 4 Wire Over 2 Wire","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eFAST-STAT - The Model 3000 is often used to add air conditioning to a heating system. It converts a 2-wire cable into a 4-wire cable (R, W, Y, G). It can also converts a 4-wire cable into a 6-wire cable for 2-stage heating, 2-stage cooling or heat pump conversions.\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eUsed to add air conditioning to a heating system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eConverts a 2-wire cable into a 4-wire cable (R, W, Y, G)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCan also convert a 4-wire cable into a 6-wire cable for 2-stage heating, 2-stage cooling or heat pump conversions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eDescription: Three Functions Over 1-Wire\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eHow It Works\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eOutput A (GREEN wire) and output B (YELLOW wire) are linked so that when output B is on it will also switch on output A. For typical installations output A (GREEN wire) is used for “G” and output B (YELLOW wire) is used for “Y” so does not create any problems as the fan will be on with the when the air conditioner is running.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eOutput C (WHITE wire) is independent of outputs A \u0026amp; B. It can be on by itself or at the same time as either or both outputs A or B. It is often used for the “W” function but can be used for other functions as well.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eApplication Examples\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eAdding Air Conditioning\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eA 2-wire thermostat cable can be converted to provide R, G, Y \u0026amp; W using the Model 3000.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eWi-Fi Thermostats\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eIf the thermostat cable has three or more wires, the Model 3000 can be used to add a common or “C” connection at the thermostat. This is achieved by having two or three existing functions share one wire which then frees up a wire that can then become a common wire.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eMany Wi-Fi thermostats have a self-configure option in which the thermostat automatically detects the wires connected to it in order to make easier for homeowners to install the thermostat. When using the Model 3000, do a “Reset” then select “Pro Setup” to manually configure the thermostat. There are diodes in the Model 3000 sender that often prevents the thermostat from properly autoconfiguring itself.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eAdding an Extra Functions\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eThe Model 3000 can be used to add W2, Y2, G, etc to a thermostat cable. For example the existing “W” wire can become W1, W2 \u0026amp; Y2.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eCable Repairs\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eIf a wire in a cable is broken (open circuit) or shorted to another wire or to ground, the Model 3000 can often be used to replace up to two damaged wires. \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFAST-STAT wiring extenders electronically add more wires to a control cable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSaves significant time and expense as compared to repulling of new cables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCauses no damage to walls or ceilings as compared to access holes that are often needed when re-pulling cables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThe Sender and Receiver communicate over the existing thermostat cable and\/or outdoor unit cable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eNot a wireless system and therefore avoids all the problems that wireless systems may have.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eNo batteries required. All FAST-STAT models are powered by the existing 24 volt transformer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCompatible with all conventional wiring systems using R, C, W, W2, Y, Y2, G, O\/B and other terminals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWorks with old and new systems. Can be connected to older systems such as thermopile millivolt, standing pilot systems, intermittent pilot controllers, fan centers etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCan be used with oil burners, zone controllers and other systems that require “dry contact switching”.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWorks over long cable lengths – up to 500 ft and more.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFAST-STAT Wiring Extenders do not produce interference with other electronic devices nor are they affected electronic devices that produce large amounts of interference.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eMany FAST-STAT Wiring Extenders can be used in the same building or complex without interference between units.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLow power use. Most FAST-STAT models use less than 3 watts of power. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eIt adds two wires to a cable. For example, with a 2-wire cable, it can provide R, G, Y, W connections at a thermostat and indoor unit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWith cables having more than two wires, the additional wires can be directly connected to the thermostat and indoor unit and used for any purpose.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThe Sender has six wires; Power In “R”, Power Out “R”, a Communication wire, Input A, Input B and Input C.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThe Receiver has seven wires; Power In “R”, Power Out “R”, a Communication wire, Output A, Output B, Output C and a Common “C” wire. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41471924895818,"sku":"FAS2","price":85.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/media__35542.1632770992.1280.1280.jpg?v=1720531518","url":"https:\/\/c38b33-2.myshopify.com\/products\/fast-stat-3000-thermostat-add-a-wire-4-wire-over-2-wire-html","provider":"Climatedoctors","version":"1.0","type":"link"}