{"product_id":"fast-stat-5000-thermostat-add-a-wire-6-wire-over-2-wire-html","title":"Fast Stat 5000 Thermostat Add A Wire 6 Wire Over 2 Wire","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eDescription\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eFAST-STAT 5000\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003ePRODUCT DESCRIPTION\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eThe FAST-STAT Model 5000 provides 6-wire control over 2-wire cable or 8-wire control over a 4-wire cable. With a 2-wire cable it can provide \"R\", \"C\", \"W1\",\"W2\", \"G\" and \"Y\". With a 4-wire cable it can provide \"R\", \"C\", \"W1\", \"W2\", \"G\" \", plus any other two functions such as \"H\", \"D\", \"W2\", \"Y2\" or \"O\/B\".\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eCOMMON USES\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eAdding air conditioning to a heating system or installation of a 2-stage furnace. Can also be used for heat pumps, 2-stage heating or cooling when an existing 4-wire thermostat cable is present.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFAST-STAT wiring extenders electronically add more wires to a control cable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSaves significant time and expense as compared to repulling of new cables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCauses no damage to walls or ceilings as compared to access holes that are often needed when re-pulling cables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThe Sender and Receiver communicate over the existing thermostat cable and\/or outdoor unit cable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eNot a wireless system and therefore avoids all the problems that wireless systems may have.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eNo batteries required. All FAST-STAT models are powered by the existing 24 volt transformer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCompatible with all conventional wiring systems using R, C, W, W2, Y, Y2, G, O\/B and other terminals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWorks with old and new systems. Can be connected to older systems such as thermopile millivolt, standing pilot systems, intermittent pilot controllers, fan centers etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCan be used with oil burners, zone controllers and other systems that require “dry contact switching”.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWorks over long cable lengths – up to 500 ft and more.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFAST-STAT Wiring Extenders do not produce interference with other electronic devices nor are they affected electronic devices that produce large amounts of interference.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eMany FAST-STAT Wiring Extenders can be used in the same building or complex without interference between units.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLow power use. Most FAST-STAT models use less than 3 watts of power.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eModel 5000\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eIt adds four wires to a cable. For example, with a 2-wire cable, it can provide R, C, G, Y, W1 \u0026amp; W2 connections at a thermostat and indoor unit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWith cables having more than two wires, the additional wires can be directly connected to the thermostat and indoor unit and used for any purpose.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThe Sender has eight wires; Power In “R”, Power Out “R”, a Communication wire, a Common wire, Input A, Input B, Input C \u0026amp; Input D.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThe Receiver has eight wires; Power In “R”, Power Out “R”, a Communication wire, Output A, Output B, Output C, Output D and a Common “C” wire. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eHow It Works\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eOutput A (GREEN wire) and output B (YELLOW wire) are linked so that when output B is on it will also switch on output A. For typical installations output A (GREEN wire) is used for “G” and output B (YELLOW wire) is used for “Y” so does not create any problems as the fan will be on with the when the air conditioner is running.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eOutput C (WHITE wire) and output D (BLUE wire) are linked so that when output D is on it will also switch on output C. For typical installations output C (WHITE wire) is used for “W1” and output D (BLUE wire) is used for “W2” so does not create any problems as heat stage-1 will be on when heat stage-2 is on.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eWhen output C or output D is on, outputs A and B will shut off. If the fan is in “manual on” mode it will shut off the fan while the heat exchanger warms up and the furnace fan control\/limit then switches on the fan. When the thermostat is in “fan manual on” mode, at the end of a heating cycle, the fan will continue to operate.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eApplication Examples\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eAdding Air Conditioning\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eA 2-wire thermostat cable can be converted to provide R, C, G, Y, W1 \u0026amp; W2 using the Model 5000.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eWi-Fi Thermostats\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eThe Model 5000 can be used to add a common or “C” connection at the thermostat. Many Wi-Fi thermostats have a self-configure option in which the thermostat automatically detects the wires connected to it in order to make easier for homeowners to install the thermostat. When using the Model 5000, do a “Reset” then select “Pro Setup” to manually configure the thermostat. There are diodes in the Model 5000 sender that often prevents the thermostat from properly autoconfiguring itself.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eAdding an Extra Functions\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eThe Model 5000 can be used to add W2, Y2, G, etc to a thermostat cable. For example the existing “W” wire can become W1, W2, G \u0026amp; Y.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eCable Repairs\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eIf a wire in a cable is broken (open circuit) or shorted to another wire or to ground, the Model 5000 can often be used to replace up to five damaged wires. \u003c\/span\u003e\u003c\/p\u003e","brand":"Rheem Parts","offers":[{"title":"Default Title","offer_id":41471921127498,"sku":"FAS3","price":122.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/FAS3__95977.1632582234.1280.1280.jpg?v=1720531447","url":"https:\/\/c38b33-2.myshopify.com\/products\/fast-stat-5000-thermostat-add-a-wire-6-wire-over-2-wire-html","provider":"Climatedoctors","version":"1.0","type":"link"}