{"product_id":"fieldpiece-tc24-pipe-clamp-thermocouple-3-8-to-1-3-8-pipe-clamp-html","title":"Fieldpiece TC24 Pipe-Clamp Thermocouple 3\/8” - 1-3\/8” AC","description":"\u003cdiv class=\"col-sm-9\"\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: large;\"\u003eTC24 - Pipe-Clamp Thermocouple 3\/8” to 1 3\/8” for Air Conditioning\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003ePipe-Clamp Thermocouple 3\/8” to 1 3\/8” for Air Conditioning – TC24\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eOverview for Fieldpiece TC24\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eThe TC24, K-type, pipe clamp thermocouple is used to take temperatures of pipes or any other cylindrical surface within its 3\/8” to 1 3\/8” jaw range. Using a pipe clamp thermocouple greatly facilitates taking superheat or subcooling measurements. Use the TC24 for most A\/C units. The TC24 can be used with any of our meters that measure temperature and any thermometer accepting a K-type thermocouple. The sensor is virtually isolated from ambient conditions, allowing the thermocouple to read the true pipe temperature for as long as it is attached. The sensor's large surface area and increased clamping force help the sensor reach the correct temperature within 30 seconds. Because the jaw is designed for HVAC\/R, its clamping ability lets you measure temperatures of pipes that are fixed, at any angle, to walls or other surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eTypical stabilization time: less than 30 seconds.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003ePlug: K-type thermocouple male mini plug.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eThermocouple conductors: K-type nickel chromium\/nickel aluminum.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eTemperature range: -50 to 257 deg. F (-46 to 125 deg. C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eAccuracy: +\/- 4 deg. F (2 deg. C) ; +\/- 1 deg. F (0.5 deg. C) after field calibration, 32 to 176 deg. F (0 to 80 deg. C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eATC1 jaw range: 3\/8\" to 1 3\/8\" pipe diameter (outside diameter)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eOur SKU number(s):\u003c\/strong\u003e Fieldpiece TC24\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eThe manufacturer model number(s):\u003c\/strong\u003e Fieldpiece TC24\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eAccuracy and Speed\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Get your pipe temperatures fast. A new sensor gives accurate readings, even in hot and windy conditions. Use the TC24 Pipe Clamp Type K Thermocouple to take temperatures of pipes or any other cylindrical surface between 3\/8\" and 1 3\/8\".\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eThe clamping range covers most sizes seen in residential and light commercial cooling systems. Connect to any thermometer with a Type K thermocouple jack.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eThe sensor is specifically designed for pipe temperature readings. Readings are extremely accurate and fast. Easily measure temperatures of pipes that are fixed, at any angle, to walls or other surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eSPECIFICATIONS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eTC24 jaw range: 3\/8” to 1 3\/8” pipe diameter (outside diameter)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Accuracy: +\/- 4ºF (2°C) ; ±1°F (0.5°C) after field calibration (meets California's Title 24 specifications), 32 to 176ºF (0 to 80°C)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Temperature range: -50 to 257ºF (-46 to 125°C)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Thermocouple conductors: K-type nickel chromium\/nickel aluminum.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Probe insulation and clamp material: Calibration and atmosphere will affect maximum useful temperature in applications. The wire insulation and clamp material are designed to withstand a maximum continuous use at 257°F (125°C).\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Plug: K-type thermocouple male mini plug.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e Typical stabilization time: less than 30 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fieldpiece Instruments","offers":[{"title":"Default Title","offer_id":41471987449930,"sku":"FIEL177","price":79.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/12706555__22912.1598949070.1280.1280.jpg?v=1720532766","url":"https:\/\/c38b33-2.myshopify.com\/products\/fieldpiece-tc24-pipe-clamp-thermocouple-3-8-to-1-3-8-pipe-clamp-html","provider":"Climatedoctors","version":"1.0","type":"link"}