{"product_id":"honeywell-db7110u1000-universal-heat-pump-defrost-control-html","title":"Honeywell DB7110U1000 Universal Heat Pump Defrost Control","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eHoneywell DB7110U1000 Universal Heat Pump Defrost Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"overview\"\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eUniversal Defrost Control for Single Stage On\/Off Heat Pumps. It provides control of the outdoor equipment; compressor contactor, reversing valve, and outdoor fan in response to thermostat requests and air and coil temperatures. It also controls the indoor auxiliary heat source that is used during defrost operations and often as a second stage of heat. A defrost cycle is triggered based on outdoor air and outdoor coil temperatures that are measured using included temperature sensors.\u003c\/span\u003e\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"specs\"\u003e\n\u003ch2\u003e\u003cspan style=\"font-size: large;\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eApplication\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSingle Stage Heat Pumps\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eIncludes\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAir temperature sensor with 2 pin connector; Coil temperature sensor with 3 pin connector; Wire leads; Wire nuts; Mounting screws\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eComments\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAll terminals except FAN-IN and FAN-OUT are NEC Class 2 low voltage; FAN-IN and FAN-OUT are line voltage.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eItem Type\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eProduct\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eMounting\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAny Orientation, but recommended to mount so display is easily readable\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eElectrical Ratings\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eMaximum Input Current: 200 mA; Compressor Contactor: 1A @ 24 Vac; Aux Heat: 1A @ 24 Vac; Reversing Valve: 1A @ 24 Vac; Outdoor Fan: 1\/2 HP motor, 5A full load, 30A locked rotor, 240 Vac.\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eFrequency\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e60 Hz\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eStages\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSingle Stage On\/Off\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eElectrical Connections\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e1\/4 in. quick connect\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperating Humidity Range (% RH)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eLess than 95% RH, non-condensing\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e24 Vac\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperating Temperature Range (F)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e-40 F to 150 F\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eLEDs\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eSystem LED, Fauult LED\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eAmbient Temperature Range (F)\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eCoil Enable: 30 F to 36 F; Termination Temperature: 50 F to 100 F; Auxiliary Lockout Temp: 0 F to 40 F; Compressor Lockout Temp: -10 F to 40 F\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eDisplay\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003e4 character 7 segment display for Menu and Settings\u003c\/span\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cspan style=\"font-size: large;\"\u003eOperation\u003c\/span\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cspan style=\"font-size: large;\"\u003eAll outputs rated for 100,000 operations\u003c\/span\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41472517668938,"sku":"DB7110U1000 HON","price":116.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/DB7110U1000__25337.1605043979.1280.1280.jpg?v=1720540015","url":"https:\/\/c38b33-2.myshopify.com\/products\/honeywell-db7110u1000-universal-heat-pump-defrost-control-html","provider":"Climatedoctors","version":"1.0","type":"link"}