{"product_id":"honeywell-s9200u1000-universal-integrated-control-board-html","title":"Honeywell S9200U1000 Universal Integrated Control Board","description":"\u003cp\u003eHoneywell S9200U1000 Universal Integrated Furnace Control Circuit Board. This board replaces many other brands of boards, such as Carrier, Goodman, ICM, Lennox, Nordyne, York, Rheem\/Robertshaw, Texas Instruments, White-Rodgers \u0026amp; Utec\u003c\/p\u003e\u003cp\u003eThe S9200U1000 Universal Integrated Furnace Control can be used with conventional thermostats as well as the EnviraCOM enabled VisionPRO IAQ and FocusPRO. It is intended for residential natural or liquid propane fueled furnaces only. The S9200U1000 EnviraCOM communications capability allows its use in twinning applications and enables communication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook 72), EnviraLINK web-based application and the W8735D Telephone Access Universal Hot Surface Ignition Integrated Furnace Control. Controls a standard induction-type circulating fan motor.\u003c\/p\u003e\u003cp\u003eFeatures\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMain burner ignition using a 120V hot surface igniter.\u003c\/li\u003e\n\u003cli\u003eFlame rectification circuit to monitor flame presence.\u003c\/li\u003e\n\u003cli\u003eMonitoring of system pressure switch, high temperature limit, and rollout functions.\u003c\/li\u003e\n\u003cli\u003eAppliance operation\/safety requirements controlled via microprocessor.\u003c\/li\u003e\n\u003cli\u003eControl of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat.\u003c\/li\u003e\n\u003cli\u003eLED system status, performance and diagnostic indication.\u003c\/li\u003e\n\u003cli\u003eWire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances.\u003c\/li\u003e\n\u003cli\u003eTwinning capability\u003c\/li\u003e\n\u003cli\u003eEnviraCOM communication capability to enable local and\/or remote system status, diagnostics, troubleshooting, and HVAC system control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecifications\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDescription: Universal single stage heating \u0026amp; cooling\u003c\/li\u003e\n\u003cli\u003eLine Voltage: 120Vac (97-132 Vac)\u003c\/li\u003e\n\u003cli\u003eLow Voltage: 24V (18-30Vac)\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eOperating Temperature (F): -40 F to +175 F\u003c\/li\u003e\n\u003cli\u003eOperating Temperature (C): -40 C to +79 C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity Range (% RH): 0% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eIgniter Current: 1.0A resistive @ 95Vac output\u003c\/li\u003e\n\u003cli\u003eThermostat Anticipator Setting: (Stage 1 only) 100mA\u003c\/li\u003e\n\u003cli\u003ePrePurge: 30 seconds\u003c\/li\u003e\n\u003cli\u003eHSI Warmup Time: 17\/27 or 30\/30 seconds\u003c\/li\u003e\n\u003cli\u003eTrial For Ignition: 4, 6, or 8 seconds\u003c\/li\u003e\n\u003cli\u003ePostPurge: 15 seconds\u003c\/li\u003e\n\u003cli\u003eInterpurge: 60 seconds\u003c\/li\u003e\n\u003cli\u003eIgnition Trials: Three, two tries if flame is not sensed\u003c\/li\u003e\n\u003cli\u003eFlame Failure Response Time: 2 Seconds max @ 1µA\u003c\/li\u003e\n\u003cli\u003eNumber of LEDs: 3\u003c\/li\u003e\n\u003cli\u003eHeat On Fan Delay: 30 or 60 seconds\u003c\/li\u003e\n\u003cli\u003eHeat Off Fan Delay: 60, 90, 120, or 180 Seconds\u003c\/li\u003e\n\u003cli\u003eCool Fan On Delay: 5 seconds\u003c\/li\u003e\n\u003cli\u003eCool Fan Off Delay: 0 or 60 seconds\u003c\/li\u003e\n\u003cli\u003eGas Control Used With: Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.\u003c\/li\u003e\n\u003cli\u003eCooling Contactor Used With: Any 24Vac contactor rated at 1.0A or less\u003c\/li\u003e\n\u003cli\u003eInduced Draft Blower Load: 2.2FLA \/ 25LRA max @120Vac\u003c\/li\u003e\n\u003cli\u003eCirculator Load: 14.5FLA \/ 25LRA max @120Vac\u003c\/li\u003e\n\u003cli\u003eType of Fan Used With: Standard Induction-Type Circulating Fan \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e***THIS CONTROL COMES COMPLETE WITH ALL WIRING HARNESSES NEEDED FOR YOUR CONVERSION!***\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471605866570,"sku":"HONE127","price":140.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2516417__16238.1560439538.1280.1280.jpg?v=1720527232","url":"https:\/\/c38b33-2.myshopify.com\/products\/honeywell-s9200u1000-universal-integrated-control-board-html","provider":"Climatedoctors","version":"1.0","type":"link"}