{"product_id":"honeywell-thx321wfs3001w-t10-pro-smart-with-redlink-thermostat-ias","title":"Honeywell THX321WFS3001W T10+ Pro Smart with RedLINK thermostat + IAS","description":"\u003cdiv class=\"overview\"\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe T10+ Pro Smart Thermostat utilizes both RedLINK® and Wi-Fi capabilities. It allows homeowners to prioritize spaces in their house where they want to direct their comfort. Up to 4H\/2C Heat Pump or 3H\/2C Conventional (with EIM), Geofencing and flexible programmability available. Utilizes the Resideo App. ENERGY STAR® Certified.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdl\u003e\n\u003cdt\u003e\n\u003cp\u003eApplication\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e24 Vac systems, up to 3H\/2C heat pump or 2H\/2C conventional. Gas, Oil, Electric, Steam \/ Gravity Systems \u0026amp; dual fuel\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eDimensions (in.)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e4.9\" H x 3.7\" W x 0.93\" D\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eDimensions (mm)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e125.4mm x 94.1mm x 23.68mm\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eIncludes\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThermostat, UWP mounting system, cover plate, mounting hardware, \u0026amp; wireless indoor sensor\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eMounting\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eUWP Mounting System\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eElectrical Ratings\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e20 to 30 Vac\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eFrequency\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e50 Hz; 60 Hz\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eStages\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eUp to 3 Heat\/2 Cool Heat Pumps; Up to 2 Heat\/2 Cool Conventional Systems\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eElectrical Connections\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eUWP Mounting System\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eOperating Humidity Range (% RH)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e5 to 90% RH, non-condensing\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eSupply Voltage\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e20 to 30 Vac\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eSwitch Positions (System)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eHEAT-OFF-COOL-AUTO-EM HEAT\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eSwitch Positions (Fan)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eAUTO-ON-CIRC-FOLLOW SCHEDULE\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eOperating Temperature Range (F)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e37 F to 102 F\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eOperating Temperature Range (C)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e2.7 C to 39 C\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eShipping and Storage Temperature Range (F)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e- 20 F to 120 F\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eShipping and Storage Temperature Range (C)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e- 28.9 C to 48.9 C\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eApprovals, Federal Communications Commission\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eFCC: 47 CFR § 15.19 (a)(3), 47 CFR § 15.21 (USA only), \u0026amp; 47 CFR § 15.105 (b). IC REGULATIONS: RSS-GEN\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eNetwork Communications\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eWi-Fi\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003ePower Method\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eHardwired\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eAmbient Temperature Range (C)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e0 C to 50 C\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eAmbient Temperature Range (F)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e32 F to 120 F\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eColor\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eWhite\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eTouch screen\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eSensor Element\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eRelay\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eProgrammability\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e7 day, 5-1-1 day, 5-2 day, 1 week, or Non-programmable. Can use sensors for priority scheduling.\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eTerminal Designations\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eRC, R, C, W, O\/B, Y, Y2, G, E, AUX, K, L, U, U, S, S\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eDisplay Size\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e7.27 sq. in.\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eTemperature Control Mode Selections\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eAmbient Air Temperature\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eChangeover\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eAuto or Manual\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eSetting Temperature Range (F)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eHeat: 40 F to 90 F; Cool 50 F to 99F\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eSetting Temperature Range (C)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eHeat: 4.5 C to 32.0 C; Cool: 10 C to 37.0 C\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eHumidification Setting Range\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e0% to 90% RH\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eDehumidification Setting Range\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e10% to 100% RH\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eCool Current\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e0.02 A to 1.0 A running\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eHeat Current\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e0.02-1.0 A\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eFan Current\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003e0.02-.05 A\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eExternal Sensors Available\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eC7189R3002 Wireless RedLINK Indoor temperature\/humidity\/motion included. C7089R3013 optional wireless outdoor temperature \u0026amp; humidity sensor, C7189U1005 wired indoor sensor, C7089U1006 wired outdoor sensor, AC112-01 floor slab sensors ordered separate\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eParts Needed for Operation (not included)\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eTHM04R3000 EIM available separate or in the YTHM1004R kits\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eTransmitter Range\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eFor RedLINK Transmitter - Max distance for open air line-of-site is about 1500 feet. This may be reduced depending on materials in-between the radios. It is up to 200 ft in a typical home.\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003cdt\u003e\n\u003cp\u003eTransmitter Frequency\u003c\/p\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eRedLINK Transmitter - 900 Mhz frequency range\u003c\/p\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41917031088202,"sku":"THX321WFS3001W","price":263.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/THX321WFS2001W-HON.jpg?v=1739119612","url":"https:\/\/c38b33-2.myshopify.com\/products\/honeywell-thx321wfs3001w-t10-pro-smart-with-redlink-thermostat-ias","provider":"Climatedoctors","version":"1.0","type":"link"}