{"product_id":"honeywell-v8043e1061-2-way-normally-closed-3-4-sweat-24vac-zone-valve-html","title":"Honeywell V8043E1061 2 Way Normally Closed, 3\/4', Sweat, 24Vac Zone Valve","description":"\u003cp\u003eHoneywell model V8043E1061 24V 50\/60Hz Two Position Spring Return Normally Closed Straight Through zone valve With Spst End Switch. Has 3\/4 inch copper solder connections, high capacity. Valve Opens When Energized. Controls Flow Of Hot And\/Or Cold Water W\/Manual Opener. 3\/4 wire leads. 8 Cv flow rating with 8 Psi Close-Off.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eON-OFF and two-way low voltage valve\u003c\/li\u003e\n\u003cli\u003eManual opener for valve operation on power failure\u003c\/li\u003e\n\u003cli\u003eComplete powerhead may be removed or replaced without breaking connections or draining the system\u003c\/li\u003e\n\u003cli\u003eActuator motor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003cli\u003eChilled water models available for cooling and heating applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eTwo-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. \u003c\/p\u003e\u003cdiv class=\"overview\" style=\"outline: none; background-color: #ffffff;\"\u003e\u003cp style=\"outline: none; line-height: 14px; margin: 0px; padding-bottom: 7px;\"\u003e\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"features\" style=\"outline: none; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"outline: none; margin: 0px 0px 2px; border-bottom: none; line-height: 20px; padding: 0px;\"\u003e\u003cspan style=\"font-size: medium;\"\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp style=\"outline: none; line-height: 14px; margin: 0px; padding-bottom: 7px;\"\u003e\u003c\/p\u003e\n\u003cul style=\"outline: none; margin: 0px 0px 15px; padding: 0px 0px 0px 15px;\"\u003e\n\u003cli style=\"outline: none;\"\u003eManual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eAll models may be installed without disassembling the valve.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eCompact construction for easy installation.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eComplete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.\u003c\/li\u003e\n\u003cli style=\"outline: none;\"\u003eActuator motor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"outline: none; line-height: 14px; margin: 0px; padding-bottom: 7px;\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"specs\" style=\"outline: none; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"outline: none; margin: 0px 0px 2px; border-bottom: none; line-height: 20px; padding: 0px;\"\u003e\u003cspan style=\"font-size: medium;\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdl style=\"outline: none; overflow: hidden; margin: 0px;\"\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eApplication\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eHydronic Control\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDimensions (in.)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e4 in. high x 3 1\/2 in. wide x 2 3\/8 in. deep\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDimensions (mm)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e102 mm high x 89 mm wide x 60 mm deep\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eComments\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eUse this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water. Valve designed for cycling (not constantly powered on) applications.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFrequency\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e50 Hz; 60 Hz\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eApprovals, Underwriters Laboratories Inc.\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eUL Listed: File MH11826\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eOperating Humidity Range (% RH)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e5 to 95% relative humidity, non-condensing.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eVoltage\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e24 Vac; Power Consumption--7.7 VA\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eTiming\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eNominal Open--15 sec\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAmbient Temperature Range (F)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e125 F Maximum\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAmbient Temperature Range (C)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e52 C Maximum\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eConnection Type\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eSweat\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eBody Pattern\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eTwo-way, Straight-through\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003ePipe Size (inch)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e3\/4 in.\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003ePipe Size (DN)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eDN20\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCurrent Draw\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e0.32A\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFluid Temperature (C)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e10 C to 93 C\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eFluid Temperature (F)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e50 F to 200 F\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaximum Differential Pressure Ratings (Close-off) (psi)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e8 psi\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaximum Differential Pressure Ratings (Close-off) (kPa)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e55 kPa\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eElectrical Connections (in.)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e18 in. leads\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eElectrical Connections (mm)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e457 mm leads\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCapacity (Cv)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e8 Cv\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eCapacity (Kv)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e6.9 Kv\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eValve Action\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eSpring return to close\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eValve Type\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eZone Valve\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Body)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBrass\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Seat)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBrass\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Stem)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eStainless Steel\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eEnd Switch Rating\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e50 VA pilot duty @ 24 V; 4.4 A running with 26.4 A inrush @ 120 V\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eActuation\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eTwo position\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eDe-energized Position\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eNormally Closed\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eAuxiliary End Switch\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eN.O. SPST\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eStatic Pressure Rating (psi)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e125 psi\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eStatic Pressure Rating (kPa)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003e862 kPa\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Plug\/Ball\/Disc)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eBuna-N (NBR) Rubber Ball\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eMaterials (Packing)\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eEPDM rubber\u003c\/dd\u003e\n\u003cdt style=\"outline: none; float: left; width: 300px; margin: 0px 5px 5px 0px; clear: left;\"\u003eManual Opener\u003c\/dt\u003e\n\u003cdd style=\"outline: none; float: left; width: 350px; margin: 0px 0px 5px;\"\u003eYes\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":41471661244490,"sku":"HONE71","price":93.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/2515796__19975.1512177452.1280.1280.jpg?v=1720527846","url":"https:\/\/c38b33-2.myshopify.com\/products\/honeywell-v8043e1061-2-way-normally-closed-3-4-sweat-24vac-zone-valve-html","provider":"Climatedoctors","version":"1.0","type":"link"}