{"product_id":"icm1503-oil-burner-45-sec-replaces-honeywell-r8184g4009-html","title":"ICM1503 Oil Burner 45 Sec Replaces Honeywell R8184G4009","description":"\u003cp\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eDescription\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eControls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eSolid state flame sensing circuit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eLED on terminal strip indicates system lockout \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eEnclosed safety switch with external reset button \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eMounts on standard 4x4 J-Box (select models may be mounted directly on burner housing) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eC554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif;\"\u003e\u003cspan style=\"font-size: medium;\"\u003eDirect replacement for popular competitive models\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eIgnition Type: Intermittent \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eTiming, Safety Switch: 45 \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eMounting Bracket: Standard 4x4 J-Box or direct mounting on burner housing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eElectrical Rating (\u003cem\u003eContacts - Full Load):\u003c\/em\u003e 7.4 A @ 120 VAC; 3.7 A @ 240 VAC \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eElectrical Rating (\u003cem\u003eContacts - Locked Rotor\u003c\/em\u003e): 44.4 A @ 120 VAC; 22.2 A @ 240 VAC \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eDimensions: 4 3\/8\"H x 4 1\/8\"W x 2 1\/2\"D (111mmH x 104mmW x 64mmD) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eTemperature Range: -30\u003cspan\u003e½\u003c\/span\u003eF to 130\u003cspan\u003e½\u003c\/span\u003eF \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif; font-size: medium;\"\u003eApprovals: UL Approved\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Arial Narrow';\"\u003e\u003cbr\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif;\"\u003e\u003cspan style=\"font-size: small;\"\u003eR8184G1005 HWR8184G1286 624503 R8184G 42-22770-01 R8184G1427 R8184G1310 R8184B1295 P691-R8484G R8184G4009 R8184G1427 R8184G1286 CARR8184G4009 \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'Arial Narrow';\"\u003e\u003cspan style=\"font-family: verdana, arial, helvetica, sans-serif;\"\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eUsed in Rheem Ruud Furnace Models:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eROBC-150RBJA R0BC-150RBJA U0BC-150RBJA W0BC-150RBJA R0BC150RBJA U0BC150RBJA W0BC150RBJA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471666782282,"sku":"ICM1503","price":96.31,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/4602060__28837.1506005530.1280.1280.jpg?v=1720527877","url":"https:\/\/c38b33-2.myshopify.com\/products\/icm1503-oil-burner-45-sec-replaces-honeywell-r8184g4009-html","provider":"Climatedoctors","version":"1.0","type":"link"}