{"product_id":"icm493-single-phase-line-monitor-with-surge-protection-html","title":"ICM493 Single Phase Line Monitor with Surge Protection","description":"\u003cdiv class=\"box-description\"\u003e\u003cdiv class=\"col-discript\"\u003e\n\u003cdiv class=\"box-info\"\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: large;\"\u003eDescription:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eThe ICM493 is an advanced, single-phase line voltage monitor with a bank of surge arresters for added protection against lightning strikes. Includes a built-in 40A contactor. Ideal for Mini-Splits or other valuable, single-phase equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eThe ICM493 is an advanced, single-phase line voltage monitor with a bank of surge arresters for added protection against lightning strikes. Includes a built-in 40A contactor. Housed in a NEMA Rated 3R enclosure for outdoor installations. UL Recognized. Installs easily between the service disconnect and the condensing unit. Ideal for Mini-Splits or other valuable, single-phase equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"details-left\"\u003e\u003cul class=\"list-subcat-list\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eProtects against over and under voltage, rapid short cycling caused by transients, and high-power surges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eIdeal for mini-splits or other condensing units\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eEasy to view, backlit digital display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eBank of five L-L Surge Arresters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eBuilt-in 40A Contactor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWaterproof, NEMA–rated 3R enclosure for outdoor use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eEasy installation and setup\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"box-info\"\u003e\n\u003ch3 class=\"title-discript\"\u003e\u003cspan style=\"font-size: large;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eUser Adjustable Settings\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cul class=\"list-subcat-list\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eVoltage Setpoint: \u003c\/strong\u003e200-240 VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eAnti-Short Cycle Delay: \u003c\/strong\u003e0.5-10 Minutes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eNumber of Surge Arresters Required for Operation: \u003c\/strong\u003e0-5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eNumber of Retries:\u003c\/strong\u003e 1-5, Auto  \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eLine Voltage: \u003c\/strong\u003e180-264 VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eFrequency: \u003c\/strong\u003e50-60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eAccuracy: \u003c\/strong\u003e+\/- 2%, User Calibration  \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eType: \u003c\/strong\u003eContactor; 2-Pole\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eContactor Ratings: \u003c\/strong\u003e40A FLA, 240A LRA  \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eNEMA Rated 3R Outdoor Enclosure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eDimensions: \u003c\/strong\u003e8”L x 8”W x 4”H\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"box-info\"\u003e\n\u003ch3 class=\"title-discript\"\u003e\u003cspan style=\"font-size: large;\"\u003eWeight\/Dimensions:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-subcat-list list-subcat-list-big\" style=\"list-style-type: none;\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWeight: 7.55\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eHeight: 4\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWidth: 8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLength: 8\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"Icm Controls","offers":[{"title":"Default Title","offer_id":41471971688522,"sku":"ICM493","price":287.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/12648596__32498.1507827080.1280.1280.jpg?v=1720532459","url":"https:\/\/c38b33-2.myshopify.com\/products\/icm493-single-phase-line-monitor-with-surge-protection-html","provider":"Climatedoctors","version":"1.0","type":"link"}