{"product_id":"sunstar-sg10-100k-btu-infrared-radiant-nat-gas-heater-html","title":"Sunstar SG10 100K BTU Infrared Radiant Nat Gas Heater","description":"\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eWhether you need to heat your warehouse, machine shop, or other hard-to-heat spaces, the SunStar StarGlo ceramic infrared heater provides both the fuel efficiency of radiant heat and the installation flexibility you need . . . and all at a comfortable price\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: large;\"\u003eThe SunStar StarGlo\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: large;\"\u003eSG Series\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: large;\"\u003eDirect Spark Ignition\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eCERAMIC INFRARED HEATER\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eThe SunStar StarGlo is the answer for spot or area heating and for total building heating needs. It is also ideal for the replacement of existing ceramic heaters, over 10 million of which have been sold in North America since the early 1950’s. The SunStar StarGlo heats like the sun by transferring radiant heat energy directly into the area to be heated and creating a warm comfort zone at the floor level. This extremely efficient method of heating can result in fuel savings of between 30% and 50% when compared to forced air convection heating.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eWIDE VARIETY OF APPLICATIONS\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eSunStar StarGlo Ceramic heaters are ideal for many heating needs. The best applications are those where doors open and close frequently and in buildings where ceiling heights are above twelve feet. These flexible SunStar infrared heaters can meet most commercial and industrial heating needs. \u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eCeramic Infrared Heating is the answer for spot or area heating and for total building heating needs. It is also ideal for the replacement of existing ceramic heaters. SunStar Ceramic Heaters heat like the sun by transferring radiant heat energy directly into the area to be heated and creating a warm comfort zone at the floor level. This extremely efficient method of heating can result in fuel savings of between 30% and 50% when compared to forced air convection heating.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCapacities from 30,000 to 155,000 Btu\/hr\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eDimpled tile assembly design for increased radiant efficiency\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eDesign certified for angle mounting up to 30 degrees\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eEquipped with 100% gas shut-off safety control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eConstructed of aluminized steel for corrosion resistance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eAluminum reflectors designed to maximize radiant output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eOptional protective radiant screen\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCompact size for UPS shipping\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eManufacturing Plants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eWarehouses\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eAuto Dealerships\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eAircraft Hangars\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eLoading Docks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFire Stations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCommercial Garages\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eMachine Shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eTennis Courts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eMaintenance Shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFarm Buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eTruck Service Areas\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eNot Recommended for Residential Use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eAbout This Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eDirect Spark Ignition System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e120 VAC \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e0.40 Amp \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eIncludes 120\/24 V Transformer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003e1\/2 NPT Female Gas Connection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eModel: SG10\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eGas Type: Natural Gas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eInput BTU\/HR: 100,000\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eNumber of Burners:3\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eMinimum Mounting Height:15'\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eSG Supply Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eGas Type: Natural Gas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eBurner Pressure (Water Column): 6\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSupply Pressure (Water Column) MIN:7\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSupply Pressure (Water Column) MAX: 14\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eDirect Spark Ignition System. 120 VAC. 0.40 Amp. Includes 120\/24 V Transformer. 1\/2 NPT Female Gas Connection.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eSG Clearances to Combustibles (Mounted Horizontally)*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eModel: SG10\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eSides: 49\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eCeiling: 65\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eBelow: 129\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003ew\/Reflector Extension: 181\"\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cstrong\u003eSG Clearances to Combustibles (Mounted 30° Angle)*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eModel: SG10\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eBelow: 129\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003ew\/Reflector Extension: 181\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eFront: 61\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003ew\/Reflector Extension: 85\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: large;\"\u003eRear: 49\"\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e*Minimum mounting angle of 10 degrees. Observe all required clearances as shown. Clearances are measured from the reflector edge.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #ff0000; font-size: large;\"\u003e\u003cstrong\u003eWARNING: \u003c\/strong\u003eThis heater is not approved for any residential installation including home, residential, garage, or recreational use (mobile home, RV’s, campers, etc.). For residential garage applications sunstar recommends SIR Series vented tube heaters.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e** This unit is Natural Gas**\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eCOMBUSTION AIR AND VENTILATION\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eCombustion air and venting requirements for all gas-fired heating equipment must be provided per the National Fuel Gas Code NFPA54 and CAN B149 or the authority having jurisdiction over the installation. Refer to Installation and Operation Instructions for further information. An indirect vented installation requires a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of total installed heater capacity on natural gas by either gravity or power ventilation (4.18 CFM per 1000 Btu\/hr on propane). For indirect vented applications, building exhaust openings must be located above the level of the heaters and the inlet air openings must be located below the level of the heaters.\u003c\/p\u003e\u003cp\u003eFOR YOUR SAFETY OPERATE SUNSTAR GAS INFRARED HEATERS WITH PROPER CARE AND OBSERVE ALL SAFETY PRECAUTIONS. Installation and service must be performed by a licensed contractor. The installation must conform with local codes. In the absence of local codes, the installation must conform with the National Fuel Gas Code ANSI Z223.1 (latest edition also known as NFPA 54) or CAN B149 installation codes (latest edition). These codes are available from ANSI, 1430 Broadway, New York, NY 10018, the National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02269 or C.S.A. 55 Scarsdale Road, Toronto, Ontario M3B 2R3 Canada.\u003c\/p\u003e","brand":"Sunstar Heaters","offers":[{"title":"Default Title","offer_id":41471816958026,"sku":"SUNS15","price":675.12,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0571\/3549\/7290\/files\/13966057__52366.1504749132.1280.1280.jpg?v=1720529280","url":"https:\/\/c38b33-2.myshopify.com\/products\/sunstar-sg10-100k-btu-infrared-radiant-nat-gas-heater-html","provider":"Climatedoctors","version":"1.0","type":"link"}